Assembling the SPS 100
During assembly, check that all O-rings are properly positioned before fitting each component, and that
all components are clean and lubricated.
Fitting the seal housing
The two versions of the SPS 100 pump seal housing: left,
where no static flushing system is fitted; right, where a
static flushing system is fitted
•
Push the reassembled seal housing into position, castellations first. Make sure it is pressed all the
way home. This can be done using the special tools as pushers, or using a special cylindrical tool
which is available from MasoSine. Note: If a static flushing device is to be fitted, align the threaded
sockets on both sides of the seal housing vertically, so they are central to the top hole in the
bearing housing. See "The static flushing device" on page 83.
Fitting the static face and the mechanical seal—SPS 100 pumps with a single mechanical seal
•
Check that the static face’s O-ring is properly positioned and that the O-rings either side of the
mechanical seal are properly positioned.
The static face with its O-ring, left,
and the mechanical seal with one
of its O-rings visible. The surfaces
of the two components seen here
must come together on reassembly.
The back bushing is seen, right
m-SPS-en-08
43
Summary of Contents for SPS 100
Page 16: ...9 1 Dimensions in millimetres SPS 100 16 m SPS en 08 ...
Page 92: ...25 1 Pumps SPS 100 92 m SPS en 08 ...
Page 95: ...SPS 200 with cast iron power frame m SPS en 08 95 ...
Page 98: ...SPS 200 with stainless steel power frame 98 m SPS en 08 ...
Page 101: ...SPS 250 with stainless steel power frame m SPS en 08 101 ...
Page 104: ...SPS 300 with cast iron power frame 104 m SPS en 08 ...
Page 107: ...SPS 300 with stainless steel power frame m SPS en 08 107 ...
Page 110: ...SPS 400 with cast iron frame 110 m SPS en 08 ...
Page 113: ...SPS 400 with stainless steel frame m SPS en 08 113 ...
Page 116: ...SPS 500 with stainless steel power frame 116 m SPS en 08 ...