Fitting the dynamic ring holder—SPS 200 pumps with a single mechanical seal
The dynamic ring holder
•
Push the dynamic ring holder over the pump shaft, narrow end first. The dynamic ring holder has an
alignment lug inside it which must be aligned with the shaft splines.
Fitting the backing ring and the rear liner—SPS 200 pumps with a single mechanical seal
The backing ring
•
Push the backing ring over the pump shaft and over the dynamic ring holder. The backing ring is
reversible.
•
Push the rear liner into position below the backing ring. The anti-rotation pins within the pump
housing (arrowed) guarantee that the liner is properly positioned. The two liners are identical.