3 - 17
1
2
1
CLEAN
Dry air filter cartridge
When used in very dusty atmospheres there are pre-filtration elements (
e
FILTER
ELEMENTS AND BELTS). The cartridge checking and cleaning interval must also be reduced.
t
IMPORTANT
t
If the clogging indicator lamp comes on, this operation must be carried out as soon as possible (within a maximum of 1
hour). Never use the lift truck without an air filter or with an air filter that is damaged.
Respect the safety distance of 30 mm between the air jet and the cartridge to avoid tearing or piercing the cartridge.
The cartridge must not be blown near the air filter box. Never clean the cartridge by tapping it against a hard surface.
Your eyes must be protected during this intervention.
Never clean the dry air filter cartridge by washing it in liquid. Do not clean by any means the safety cartridge located
inside the filter cartridge, change it for a new one if it is clogged or damaged.
-For the dismantling and refitting of the cartridge (
e
1000H: REPLACE Air filter
cartridge).
-Clean the filter cartridge using a compressed air jet (max. pressure 3 bars) directed from the top to the bottom and from
the inside towards the outside at a minimum distance of 30 mm from the cartridge wall.
-Cleaning is completed when there is no more dust on the cartridge.
-Clean the cartridge seal surface with a damp, clean lint-free cloth and grease with a silicone lubricant (MANITOU part
No.: 479292).
-Check visually the outer condition of the air filter and its mounts. Verify the condition of the hoses and their mounts also.
CLEAN
Radiator cores
t
IMPORTANT
t
In a polluting atmosphere, clean the radiator cores every day. Do not use a water jet or high-pressure steam as this
could damage the radiator fins.
-Open the engine cover.
-If necessary, clean the intake grille on the engine bonnet.
-Using a soft cloth, clean the radiator cores in order to remove as much dirt as possible.
-Clean the radiator using a compressed air jet aimed from the engine towards the
radiator, in the opposite direction to the cooling air flow.
CLEAN
Condenser wiring harness (Air conditioning OPTION)
t
IMPORTANT
t
In a polluting atmosphere, clean the radiator core every day. Do not use a water jet or high-pressure steam as this
could damage the condenser fins.
-Remove the protective grid 1 and clean it if necessary.
-Visually check whether the condenser is clean and clean it if necessary.
-Clean the condenser using a compressed air jet aimed in the same direction as
the air flow.
-Clean with the fans running for best results.
647732
(31/10/2019)
MT
625
H
75K
ST5
S1
/ MT
625
H
75K
COMFORT
ST5
S1
Summary of Contents for MT 625 H 75K COMFORT ST5 S1
Page 6: ...1 2 647732 31 10 2019 MT 625 H 75K ST5 S1 MT 625 H 75K COMFORT ST5 S1...
Page 7: ...1 3 647732 31 10 2019 MT 625 H 75K ST5 S1 MT 625 H 75K COMFORT ST5 S1...
Page 13: ...1 9 647732 31 10 2019 MT 625 H 75K ST5 S1 MT 625 H 75K COMFORT ST5 S1...
Page 21: ...1 17 647732 31 10 2019 MT 625 H 75K ST5 S1 MT 625 H 75K COMFORT ST5 S1...
Page 33: ...1 29 647732 31 10 2019 MT 625 H 75K ST5 S1 MT 625 H 75K COMFORT ST5 S1...
Page 39: ...2 1 2 DESCRIPTION 647732 31 10 2019 MT 625 H 75K ST5 S1 MT 625 H 75K COMFORT ST5 S1...
Page 40: ...2 2 647732 31 10 2019 MT 625 H 75K ST5 S1 MT 625 H 75K COMFORT ST5 S1...
Page 51: ...2 13 647732 31 10 2019 MT 625 H 75K ST5 S1 MT 625 H 75K COMFORT ST5 S1...
Page 55: ...2 17 647732 31 10 2019 MT 625 H 75K ST5 S1 MT 625 H 75K COMFORT ST5 S1...
Page 86: ...2 48 647732 31 10 2019 MT 625 H 75K ST5 S1 MT 625 H 75K COMFORT ST5 S1...
Page 87: ...3 1 3 MAINTENANCE 647732 31 10 2019 MT 625 H 75K ST5 S1 MT 625 H 75K COMFORT ST5 S1...
Page 123: ...3 37 647732 31 10 2019 MT 625 H 75K ST5 S1 MT 625 H 75K COMFORT ST5 S1...
Page 126: ...3 40 647732 31 10 2019 MT 625 H 75K ST5 S1 MT 625 H 75K COMFORT ST5 S1...
Page 128: ...4 2 647732 31 10 2019 MT 625 H 75K ST5 S1 MT 625 H 75K COMFORT ST5 S1...