![Mahindra Maxximo Mini Van Vx 2012 Diagnostic Manual Download Page 83](http://html1.mh-extra.com/html/mahindra/maxximo-mini-van-vx-2012/maxximo-mini-van-vx-2012_diagnostic-manual_3697842083.webp)
Diagnostic Manual MAN-00183
MAXXIMO
MINIVAN
VX June 2012
/
Rev
1
The reproduction, translation, transmission, in part of
or
whole of the present document are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any
person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution.
© 2012 Mahindra &
Mahindra Ltd.
83
RAIL PRESSURE DEVIATION
Sl No
DTC
Description
1
P1496
maximum rail pressure exceeded
NORMAL OPERATION
The rail pressure is within the limit based on the engine speed
DTC Detecting Condition
Probable Causes
The rail pressure is above the maximum limit based on the
engine speed
PCV stuck closed
PCV supplied with power due
to electrical error
LAMP STATUS
Engine check lamp continuously ON
FAULT REACTION
Engine low idle RPM set at 1200 .
The accelerator pedal will respond but the maximum RPM is set as 2000 with quantity limitations