Sl No
DTC
Description
1
P1536
Demister Circuit open load error
2
P1535
Demister Circuit Short circuit to ground
3
P1534
Demister Circuit
Short circuit to battery
4
P1537
Demister Circuit over temperature Power Stage error
NORMAL OPERATION
When the Demister Switch is pressed the Demister Relay is energized by providing ground to the Demister Blower
Motor Relay which in turn provided 12V supply from the battery to the Demister blower motor at a single speed.
DTC Detecting Condition
Probable Causes
Demister circuit short to ground
Demister circuit short to battery
Demister Circuit open load error
Harness or Connectors
Failed Demister Blower
motor Relay
LAMP STATUS
Engine check lamp OFF
FAULT REACTION
Demister Stops working.