![Mahindra Maxximo Mini Van Vx 2012 Diagnostic Manual Download Page 210](http://html1.mh-extra.com/html/mahindra/maxximo-mini-van-vx-2012/maxximo-mini-van-vx-2012_diagnostic-manual_3697842210.webp)
Diagnostic Manual MAN-00183
MAXXIMO
MINIVAN
VX June 2012
/
Rev
1
The reproduction, translation, transmission, in part of
or
whole of the present document are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any
person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution.
© 2012 Mahindra &
Mahindra Ltd.
210
SENSOR SUPPLY MONITORING 2
The sensor supply voltage is monitored by a comparator. If the sensor supply voltage lies outside the thresholds, an
error is registered
NORMAL OPERATION
ECU monitors the supply voltage of the APP2 sensor of the accelerator pedal sensor and is within the
range (3.0 to 3.5 Volts for C04 and 4.75 to 5.25Volts for C55)
DTC Detecting Condition
Probable Causes
The input voltage to APP2 sensor of the accelerator pedal is not
within the range
Harness or connectors
Faulty Accelerator pedal
sensor
LAMP STATUS
Engine check lamp continuously ON
FAULT REACTION
The engine runs with throttle till 40% with fuel quantity limitations
Sl No
DTC
DESCRIPTION
1
P1646
Error in sensor supply voltage 2
Summary of Contents for Maxximo Mini Van Vx 2012
Page 274: ......