81
C. Limit
alarm
• The applicable working range limit display flashes in
orange.
• The tri-colour revolving working status lamp illuminates
in yellow.
• The announcement is given and the alarm generates
continuous sound “peep”.
The alarm buzzer is activated only when the operation
lever is turned on.
• Operation of the boom’s danger side stops automatically.
1. Lifting height upper limit switch
Use this switch to set or reset the upper limit value for the lifting
height.
While the lifting height limit is imposed by detecting the boom tip
height, the display panel displays the lifting height when the hook
is hoisted up to the over-hoisting detected state.
[Setting]
Set the boom to the desired lifting height in a condition in which
no upper limit value is set, and press and hold the switch.
The monitor display changes to the orange color and the lifting
height is set as the upper limit value.
NOTES
• Before performing a practical operation, be sure to check if the boom automatically stops when it
reaches the specified lifting height limit. If the boom does not stop, set the upper limit for the lifting
height again by repeating the above procedure.
• When the boom is in the warning alarm zone or upper limit stop state, an alarm sounds intermittently
only if raising operation or extension operation is performed.
•
The set value is memorized when the starter switch is turned to the “OFF” position.
When the boom is in the prediction zone or upper limit stop state in a condition in which the lifting height is
set, the monitor display illuminates in orange.
[Resetting]
Press and hold the switch in a condition in which the upper limit value is set. The monitor display changes
to the black colour and the upper limit value setting is cancelled.
Summary of Contents for CC423S-1
Page 2: ......
Page 8: ...vi This Page Intentionally Left Blank...
Page 22: ...14 This Page Intentionally Left Blank...
Page 56: ...48 SAFETY LABEL LOCATIONS 2 2...
Page 59: ...51 24 Machine Mass 542 4773100 28 Working Radius Rated Total Load Chart 542 3582200...
Page 60: ...52 30 Safe Operation 557 3494500 31 Operating the Moment Limiter 542 2250000...
Page 194: ...186 This Page Intentionally Left Blank...
Page 232: ...224...
Page 248: ...240 This Page Intentionally Left Blank...
Page 251: ...243 2 SPECIFICATION DIMENSIONAL DRAWING...
Page 255: ...247 4 WORKING RADIUS LIFTING HEIGHT 4 Fall Wire Rope...
Page 256: ...248 This Page Intentionally Left Blank...
Page 262: ...254 3 MONITOR INDICATION 1 Searcher hook selector switch 2 Searcher hook position display...
Page 276: ......
Page 277: ......
Page 278: ......