72
2.3.2 FUNCTIONS OF MOMENT LIMITER
•
Do not remove, disassemble, or repair the detector. In addition, do not reposition the detector
from the original location to another.
•
When an object hits the detector or damage is found on it, be sure to check the operating
condition of the automatic stop. If an abnormality occurs during automatic stop operation
due to a failed detector, be sure to repair it.
•
The slewing operation does not stop automatically when the crane is overloaded. When
overloaded, do not perform slewing operation.
•
When the boom is approaching the stop position while in operation, be sure to lower the
operation speed of the boom.
Operating the boom at high speeds may result in a serious accident, such as death or serious
injury. The boom may fail to stop at the predetermined position, causing the machine to
overturn.
•
The override switch has the function of disabling the
moment limiter function. While this switch is at the
“ON” (cancel) position, the crane does not
automatically stop by the moment limiter, falling into
very dangerous conditions. Any crane operation in
such conditions will result in dropping of hoisted load,
breakage of crane boom, and/or machine tipping, and
may cause a serious accident resulting in death or
serious injury. Use this switch only when the moment
limiter fails or a load test of the crane is conducted.
Key for the switch must be detached during normal
operations.
The moment limiter is a safety device for preventing accidents arising from overload, such as dropping
hoisted loads, damaging the boom or overturning the machine.
Before starting crane operations, be sure to inspect operation of the moment limiter to make sure that
there is no abnormality.
Summary of Contents for CC423S-1
Page 2: ......
Page 8: ...vi This Page Intentionally Left Blank...
Page 22: ...14 This Page Intentionally Left Blank...
Page 56: ...48 SAFETY LABEL LOCATIONS 2 2...
Page 59: ...51 24 Machine Mass 542 4773100 28 Working Radius Rated Total Load Chart 542 3582200...
Page 60: ...52 30 Safe Operation 557 3494500 31 Operating the Moment Limiter 542 2250000...
Page 194: ...186 This Page Intentionally Left Blank...
Page 232: ...224...
Page 248: ...240 This Page Intentionally Left Blank...
Page 251: ...243 2 SPECIFICATION DIMENSIONAL DRAWING...
Page 255: ...247 4 WORKING RADIUS LIFTING HEIGHT 4 Fall Wire Rope...
Page 256: ...248 This Page Intentionally Left Blank...
Page 262: ...254 3 MONITOR INDICATION 1 Searcher hook selector switch 2 Searcher hook position display...
Page 276: ......
Page 277: ......
Page 278: ......