![Maeda CC423S-1 Operation Manual Download Page 187](http://html1.mh-extra.com/html/maeda/cc423s-1/cc423s-1_operation-manual_3362941187.webp)
179
8.4 WHEN THESE PHENOMENA HAPPEN
8.4.1 ELECTRICAL COMPONENTS
• Make sure that you contact us or our sales service agency about the actions marked with ( ) in the table.
• Ask us or our sales service agency for repair if you suspect any abnormalities or causes other than
those given below.
Abnormal phenomenon
Major cause(s)
Remedy
Dark work lights even at the highest
engine speed
• Defective wiring,
deterioration of battery
• Poorly adjusted tension of
fan belt
• Fuse failure
(• Check and repair
slackened terminals and
open circuits)
• Adjust fan belt tension
referring to the regular 250
hours maintenance
• Replacement
Lights flicker during engine
operation
Battery status indicator does not go
out even when the engine is
running
• Defective alternator
• Defective wiring
(• Replacement)
(• Inspection and repair)
Abnormal noise from alternator
• Defective alternator
(• Replacement)
Starter not rotating even after the
starter switch is operated
• Defective wiring
• Insufficient battery charge
• Fuse failure
(• Inspection and repair)
• Charge the battery
• Replacement
Starter pinion going in and out
repeatedly (struggling)
• Insufficient battery charge
• Charge the battery
Starter key turning slow
• Insufficient battery charge
• Starter fault
• Charge the battery
(• Replacement)
Starter disengaged before the
engine starts
• Defective wiring
• Insufficient battery charge
(• Inspection and repair)
• Charge the battery
Glow lamp does not light.
• Defective wiring
• Lamp fault
(• Inspection and repair)
(• Replacement)
8.4.2 MACHINE BODY
• Make sure that you contact us or our sales service agency about the actions marked with ( ) in the table.
• Ask us or our sales service agency for repair if you suspect any abnormalities or causes other than
those given below.
Abnormal phenomenon
Major cause(s)
Remedy
Drive, slewing or boom speeds are
slow
• Insufficient hydraulic oil
• Refer to the pre-operation
inspection and fill up to the
specified amount
Abnormal noise from pump
• Clogging in the hydraulic oil
tank strainer element
• Refer to regular 2000-hour
maintenance and clean.
Hydraulic oil temperature too high
• Insufficient hydraulic oil
• Looseness of fan belt
• Refer to the pre-operation
inspection and fill up to the
specified amount
• Adjust fan belt tension
referring to the regular
250-hour maintenance
Tracks coming off
• Tracks too loose
• Refer to “Irregular
maintenance” and adjust the
tension
Abnormal wear on the sprockets
Summary of Contents for CC423S-1
Page 2: ......
Page 8: ...vi This Page Intentionally Left Blank...
Page 22: ...14 This Page Intentionally Left Blank...
Page 56: ...48 SAFETY LABEL LOCATIONS 2 2...
Page 59: ...51 24 Machine Mass 542 4773100 28 Working Radius Rated Total Load Chart 542 3582200...
Page 60: ...52 30 Safe Operation 557 3494500 31 Operating the Moment Limiter 542 2250000...
Page 194: ...186 This Page Intentionally Left Blank...
Page 232: ...224...
Page 248: ...240 This Page Intentionally Left Blank...
Page 251: ...243 2 SPECIFICATION DIMENSIONAL DRAWING...
Page 255: ...247 4 WORKING RADIUS LIFTING HEIGHT 4 Fall Wire Rope...
Page 256: ...248 This Page Intentionally Left Blank...
Page 262: ...254 3 MONITOR INDICATION 1 Searcher hook selector switch 2 Searcher hook position display...
Page 276: ......
Page 277: ......
Page 278: ......