215585
56
Revision A
$
Figure 3.116: Control Box Interior
NOTE:
If connections are reversed, the lamp will not illuminate when
the toggle switch is in field mode. Try the following to correct
the issue:
•
Check if 10 amp fuse (A) located inside the transport control
box has blown.
•
Check for short in wires to solenoid valve on header.
•
Check for incorrect wire connections (reversed) at the power
supply or solenoid valve.
$
%
&
Figure 3.117: Remote Control
5.
If your tractor does NOT have a three-pin auxiliary power
connection:
NOTE:
The remote control has internal protection which prevents
damage caused by incorrect wiring, short circuits, or
overload conditions.
Connect remote control wires (A) to the tractor
’
s power
supply as follows:
•
Connect wire (B) with no tag to tractor ground.
•
Connect wire (C) with the red tag to tractor power.
NOTE:
If the red tag is missing, identify the power by locating the
wire with the number 1 printed on it. The ground wire has
a number 2 printed on it.