© 2016 MA Lighting T e chno lo gy Gm bH | Da chde ck e rstr. 16 | D-97297 W a ldbütte lbrunn | Ge rm a ny
P ho ne +49 5251 688865-27 | suppo rt (a t) m a -do t2.co m | www.m a lighting.co m
1 of 1
Have a look at this table:
Cue
number
Fixture 1
Dim
Fixture 1
Position
1
100
Singer
2
0
Singer
3
0
Singer
4
0
Singer
5
0
Singer
6
100
Singer
We have stored fixture 1 at 100% and on the
Singer
position in cue number 1. In cue 2 it’s turned off.
Down in cue 6 it’s turned back on and it’s still used in the singer position - but it’s a tracked value (it's not actually
stored in cue 2 through 6).
Now we would like to use the same fixture in cue 3 at the drummer position.
So we turn it to 100% and selects the
Drummer
position. This is stored in cue 3.
So this is our current scenario:
Cue
number
Fixture 1
Dim
Fixture 1
Position
1
100
Singer
2
0
Singer
3
100
Drummer
4
100
Drummer
5
100
Drummer
6
100
Singer
So the new drummer position is stored in cue 3 and tracked until cue 6 where the console new that we needed the
Singer position.
Also notice that it has not protected the dimmer value in cue 6 - it's now a tracked value from cue 3.
So now we need to store the dimmer at 0% in cue 4 and cue 5. If we just do this with a normal store, then it'll track
into cue 6 and turn the dimmer off.
Take the dimmer to 0% and store (merge) cue 4 and 5 as Cue Only.
92