4
Switch Interface Administration
Digital Interfaces
UCS 1000 R4.2 Administration 585-313-507
Issue 3 April 2000 167
4
Press
F 3
(Save).
The system saves the parameter information and assigns the Digital R2
MFC - Mexico protocol to the selected E1 circuit card.
Table 12.
Parameter Values for Assign Card: Digital R2 MFC - Mexico Window
Field Name
Value
Framing/Line Coding:
CEPTHDB3
Idle Code:
01010100
DTMF Muting:
Yes
A-LAW or MU-LAW:
A-LAW
CRC:
Yes
Max. Digits in Called Number:
4
Outgoing Addressing Type:
MFC
Incoming Addressing Type:
MFC
Incoming Speech Volume:
1414
Outgoing Speech Volume:
1
1 This field is displayed only if the optional SSP Text-to-Speech package is
installed. This field applies only to SSP Text-to-Speech output volume. The
LSPS output volume cannot be changed.
707