4
Replace the currently active Timing Generator Unit.
IF ...
THEN ...
the NE does not synchronize to the
external clock source,
proceed to Step 5.
the NE synchronizes to the
external clock source,
END OF STEPS
.................................................................................................................................................................................................
5
Replace the timing interfaces TI-E1/TI-DS1.
E
N D
O F
S
T E P S
........................................................................................................................................................................................................................
Installation troubleshooting
NE synchronization failure
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
A-7