7
Select the existing
Path Protection
in the
Ptn Grp
tab on the left-hand side of the
window and click the
Select
button.
.................................................................................................................................................................................................
8
Check that “Protection” is indicated as the
Active
path.
.................................................................................................................................................................................................
9
Click
Close
.
.................................................................................................................................................................................................
10
In the
WaveStar
®
CIT
System View
, select
Fault
→
Protection Switch
{
.
Result:
The
Protection Switch
window appears.
.................................................................................................................................................................................................
11
Select the existing
Path Protection
in the
Ptn Grp
tab on the left-hand side of the
window and click the
Select
button.
.................................................................................................................................................................................................
12
From the
Switch Type
drop-down list box, select
Clear
.
.................................................................................................................................................................................................
13
Click
Apply
and then
Yes
in the confirmation window.
.................................................................................................................................................................................................
14
From the
Switch Type
drop-down list box, select
Manual To Working
.
.................................................................................................................................................................................................
15
Click
Apply
and then
Yes
in the confirmation window.
Result:
An immediate switch to the “Working” path is caused (a short traffic
interruption of about 15 ms can be observed).
.................................................................................................................................................................................................
16
From the
Switch Type
drop-down list box, select
Clear
to clear the protection switch.
.................................................................................................................................................................................................
17
Click
Apply
and then
Yes
in the confirmation window.
.................................................................................................................................................................................................
18
Click
Close
.
.................................................................................................................................................................................................
19
In the
WaveStar
®
CIT
System View
, select
View
→
Protection...
.
Network establishment and testing
SNCP/UPSR test
.................................................................................................................................................................................................................................
10-74
Lucent Technologies - Proprietary
See notice on first page
365-374-187