IF ...
THEN ...
no further DS3 ports have to be
tested
and
a DS3 protection test
shall be performed,
Skip the following steps and proceed to section
“DS3 protection test” (p. 8-27)
.................................................................................................................................................................................................
20
In the
WaveStar
®
CIT
System View
, select
Configuration
→
Cross-Connection
→
Delete
to delete the established cross-connection.
Result: Screen 1
appears.
.................................................................................................................................................................................................
21
Click the
Equip
tab on the left.
.................................................................................................................................................................................................
22
Expand the tree of the circuit pack to which the transmission analyzer is connected and
select the respective port.
Result:
In the list box on the right the existing cross-connection that shall be
deleted is displayed.
.................................................................................................................................................................................................
23
Select this cross-connection and click
Next>
.
Result: Screen 2
appears.
.................................................................................................................................................................................................
24
Select
ALL Legs
of this cross-connection and click
Next>
.
Result: Screen 3
appears. This window contains the parameters of the selected
cross-connection.
.................................................................................................................................................................................................
25
Click
Finish>
to delete the cross-connection and confirm the resulting message by
clicking
Yes
.
.................................................................................................................................................................................................
26
Click
Close
to exit the
Delete Cross Connection
window.
.................................................................................................................................................................................................
27
Repeat
to
for all the other DS3 ports that are to be tested.
Stand-alone test procedures
DS3 transmission and protection test
.................................................................................................................................................................................................................................
8-26
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005
E
N D
O F
S
T E P S
.................................................................................................................................................................................................