NOTE:
•
Select the port that is connected to NE-C as port
A
(Path 1).
•
Select the port to which the fiber loop is connected as Port
B
(Add/Drop).
•
Select the port that is connected to NE-A as port
C
(Path 2).
•
The port that is connected to NE-A must be defined as working path!
.................................................................................................................................................................................................
18
Start a remote login to NE-C.
.................................................................................................................................................................................................
19
In the
WaveStar
®
CIT
System View
, select
Configuration
→
Cross-Connection
→
Create
to set up a cross-connection.
Result:
The
Create New Cross Connection
window appears.
.................................................................................................................................................................................................
20
Select/Activate the
Signal Rate Auto Set
check box and define the cross-connection
rate in the
Rate
drop-down list box according to the analyzer signal used. The
following values are possible:
•
VC-3
(SDH) /
STS-1
(SONET)
•
VC-4
(SDH) /
STS-3
(SONET)
•
VC-4-4c
(SDH) /
STS-12
(SONET)
•
VC-4-16c
(SDH) /
STS-48
(SONET)
•
VC-4-64c
(SDH) /
STS-192
(SONET)
Please note that it is not possible to proceed to the next window before selecting the
cross-connection rate.
.................................................................................................................................................................................................
21
In the
XC Application
group box, select
2-Way Point-to-Point
.
.................................................................................................................................................................................................
22
Click the left
Select
button to select the source tributary.
Result:
The
Ptn Grp
selection tab appears.
.................................................................................................................................................................................................
23
Select the port that is connected to NE-B.
Result:
In the
Tributary
list box on the right, the AIDs of all VCs/STSs belonging
to the respective port are displayed.
.................................................................................................................................................................................................
24
Select the VC/STS which shall be used as the source and click the
Select
button.
Network establishment and testing
SNCP/UPSR test setup
.................................................................................................................................................................................................................................
10-48