Result:
The
Create New Cross Connection
window appears.
.................................................................................................................................................................................................
4
Select/Activate the
Signal Rate Auto Set
check box and define the cross-connection
rate in the
Rate
drop-down list box according to the analyzer signal used. The
following values are possible:
•
VC-3
(SDH) /
STS-1
(SONET)
•
VC-4
(SDH) /
STS-3
(SONET)
•
VC-4-4c
(SDH) /
STS-12
(SONET)
•
VC-4-16c
(SDH) /
STS-48
(SONET)
•
VC-4-64c
(SDH) /
STS-192
(SONET)
Please note that it is not possible to proceed to the next window before selecting the
cross-connection rate.
.................................................................................................................................................................................................
5
In the
XC Application
group box, select
2-Way Point-to-Point
.
.................................................................................................................................................................................................
6
Click the left
Select
button to select the source tributary.
Result:
The
Ptn Grp
selection tab appears.
.................................................................................................................................................................................................
7
Select the port to which the SDH/SONET analyzer is connected.
Result:
In the
Tributary
list box on the right, the AIDs of all VCs/STSs belonging
to the respective port are displayed.
.................................................................................................................................................................................................
8
Select the VC/STS which shall be used as the source and click the
Select
button.
.................................................................................................................................................................................................
9
Select the port to be tested as destination port and the corresponding VC/STS in the
Tributary
list box.
.................................................................................................................................................................................................
10
Click the
Select
button.
Result:
The current data of the cross-connection are displayed.
.................................................................................................................................................................................................
11
Select
NORM
as
Output Mode
in the
Source to Destination
and
Destination to
Source
group boxes.
Stand-alone test procedures
Receiver sensitivity test
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
8-17