The User Interface
142
Conveyor Setup
Purpose
The Conveyor Setup screen is displayed by tapping on the Conveyor area
in the
Service
screen.
The purpose of the screen is to enable you to set up the conveyor based on the optional items fitted
and its method of operation.
Screen Contents
Select or enter the appropriate parameter values in the screen as follows:
■
PEC enable
This option refers to the optional Product Registration Photo-eye that is located on the infeed of
the conveyor. When the option is enabled the photo-eye acts as a timing start point for both
correct detection and subsequent reject timing functions.
Tap in the option check box to enable or disable it.
■
PEC fault
This option is displayed if the PEC enable option has been selected. When the option is
enabled, should the photo-eye become blocked for any reason a system fault will be generated.
Depending on the reject and conveyor setup the conveyor will then stop and/or a reject
actuation will occur. Three options are available for selection as follows:
O
Off
Selecting this option disables the PEC fault functionality.
O
Latched
Select this option if the fault must be manually cleared after the PEC has been unblocked.
O
Auto Clear
Select this option if the fault is automatically cleared after the PEC has been unblocked.
Tap the arrow to the right of the field to display the drop down list of available noise filter
level options and select the one to be used. The PEC fault option, set to Auto Clear, is set
by default.
Summary of Contents for IQ3+
Page 2: ......
Page 36: ...Safety First 26 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 43: ...Installation 33 ...
Page 60: ...Installation 50 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 70: ...About the Metal Detector Range 60 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 218: ...Operating Instructions 208 THIS IS PAGE INTENTIONALLY LEFT BLANK ...
Page 244: ...Maintenance 234 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 248: ...Glossary 238 THIS PAGE IS INTENTIONALLY LEFT BLANK ...