The User Interface
116
■
Tolerance
This feature is used to add a percentage safety margin to the product signal threshold, captured
and set during the Learn process, to allow for any small variances in product signal values
during normal running conditions.
Tap the arrow to the right of the field to display a drop down list of options for setting the
Tolerance percentage to be used. Options of Low, Med, High and Max are available, with Med
being the default providing around 15% of tolerance.
■
Normal drive
This feature is used to set the drive level used when carrying out a Full Learn process when the
Unknown or Dry Product type option has been selected in the
Product Settings
screen.
Tap the arrow to the right of the field to display a drop down list of options for setting the drive
level to be used. Options of Low, Med, High and Max are available, with High being the default
value.
■
Metal film drive
This feature is used to set the drive level used when carrying out a Full Learn process when the
Metal film Product type option has been selected in the
Product Settings
screen.
Tap the arrow to the right of the field to display a drop down list of options for setting the drive
level to be used. Options of Low, Med, High and Max are available, with Low being the default
value.
■
PQ Gain
This feature is used to set the initial P and Q gain levels to be used when starting a Full Learn
process.
Tap the arrow to the right of the field to display a drop down list of options for setting the gain
level to be used. Options of Min, Low, Med and Max are available, with Max being the default
value.
■
RF Gain
This feature is used to set the initial RF gain level to be used when starting a Full Learn
process.
Tap the arrow to the right of the field to display a drop down list of options for setting the gain
level to be used. Options of Min, Low, Med and Max are available, with Med being the default
value.
■
Max learnt threshold
This feature is used to set the maximum signal value to be used during a Full Learn process. If
the signal exceeds this threshold then the frequency is automatically reduced.
Tap in the field to display a pop-up numeric keypad and enter the value required. The default
value is 5000.
■
Saturation learn limit
This feature is used to set the maximum saturation learn signal value to be used during a Full
Learn process. If the signal exceeds this limit then the gain or frequency is automatically
reduced.
Tap in the field to display a pop-up numeric keypad and enter the value required. The default
value is 1900.
Summary of Contents for IQ3+
Page 2: ......
Page 36: ...Safety First 26 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 43: ...Installation 33 ...
Page 60: ...Installation 50 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 70: ...About the Metal Detector Range 60 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 218: ...Operating Instructions 208 THIS IS PAGE INTENTIONALLY LEFT BLANK ...
Page 244: ...Maintenance 234 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 248: ...Glossary 238 THIS PAGE IS INTENTIONALLY LEFT BLANK ...