About the Metal Detector Range
52
Metal Detector Search Heads
To cater for the requirements of different types of product the IQ
3
+ Metal Detector Search Head is
available in a range of aperture heights and widths to suit the product to be inspected.
Standard Features
■
Variable Frequency Capability
- Loma is the only company in the industry that offers true
variable frequency, operating between 40 - 900 kHz. This means that you can configure the
same machine for use with a variety of products. Through the systems product 'Learn' feature,
the correct frequency for a product can be automatically set in seconds, eliminating past
performance restrictions caused by limited frequency metal detectors.
■
Environmental Protection Cover
– A plastic cover, mounted on hinges, is provided to go over
the touch screen to prevent the screen being damaged during cleaning operations.
Optional Features
The following optional features are supplied with a detector search head:
■
Harsh Environment Protection Liner
– This white aperture liner is made from POM C Acetyl
Copolymer and is suitable for harsh applications where the product temeprature is > 30
degrees or if hose down or steam cleaning is to be used.
■
Remote Control Kit
- The remote controls is provided with a fully enclosed IQ
3
+ control box, a
mounting kit and bracket to mount on a frame/structure with up to 10-meter cable. Remote
boxes above a 2 metre distance from the search head have a local power supply unit fitted to
run the touch screen display. A local mains power supply is required for the control box.
■
Lamp Stack
– A plastic LED lamp stack with audible alarm included (several sound alarm
available and volume adjustable) is available. The lamp base is mounted on a pole on the side
of the head and provides visual signalling as follows:
o
Red Lamp
– System Error.
o
Orange Lamp
– Detection / Rejection.
o
Green Lamp
– Normal Running / Inspection.
•
Blue Lamp
– Run Error / PVS Test.
Summary of Contents for IQ3+
Page 2: ......
Page 36: ...Safety First 26 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 43: ...Installation 33 ...
Page 60: ...Installation 50 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 70: ...About the Metal Detector Range 60 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 218: ...Operating Instructions 208 THIS IS PAGE INTENTIONALLY LEFT BLANK ...
Page 244: ...Maintenance 234 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 248: ...Glossary 238 THIS PAGE IS INTENTIONALLY LEFT BLANK ...