The User Interface
89
■
Problem:
Bin full - the reject bin full sensor has been blocked for longer than 5 seconds and
the transport system has stopped. The bin will need to be emptied before the transport can be
restarted.
O
Action:
If the bin is full:
1. Remove, identify and segregate the product. Once the sensor is unblocked the fault
will automatically clear.
If the bin is not full:
1.
Check the Bin full sensor is working correctly.
■
Problem:
Link corrupted - data corruption has occurred between the detector and LomaLink
PC or other controlling device. The operation of the detector is unaffected.
O
Action:
1. Check cabling and link connectors from remote device.
2. Check LomaLink PC or other controlling device for reported errors.
■
Problem:
Link failure - a break in communication between the detector and LomaLink PC/other
controlling device. The operation of the detector is unaffected.
O
Action:
1. Check cabling and link connectors from remote device.
2. Check connections between the detector and LomaLink PC or other controlling device
for loose or broken wiring/connectors.
■
Problem:
PV test timeout - an automated prompt for the PV test has either not been actioned
or completed within the window time set. The transport system may have stopped.
O
Action:
Clear system fault (restart the transport if stopped) and perform a
PV test
.
■
Problem:
PEC obstructed - the product registration photo-eye has remained blocked for
greater than 6 consecutive pack lengths. This fault is only generated if the PEC fault is enabled.
O
Actions:
1. Check the PEC for blockage.
2. Check the PEC is working correctly.
3. Check pack flow length entry is adequate, ensuring an allowance is made for pack
skew.
4. Ensure the correct belt speed is entered.
■
Problem:
Wrong flash c/sum - the software has compared the flash checksum currently stored
in its memory with the checksum for recently installed software. This occurs if a software
update has been done and a hardware cold start was not performed after installation.
O
Action:
1. Perform an update checksum from the tick button found in the
Search Head Setup
screen.
Summary of Contents for IQ3+
Page 2: ......
Page 36: ...Safety First 26 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 43: ...Installation 33 ...
Page 60: ...Installation 50 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 70: ...About the Metal Detector Range 60 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 218: ...Operating Instructions 208 THIS IS PAGE INTENTIONALLY LEFT BLANK ...
Page 244: ...Maintenance 234 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 248: ...Glossary 238 THIS PAGE IS INTENTIONALLY LEFT BLANK ...