The User Interface
140
■
GP I/O
The GP I/O board provides additional functionality as described below in the
GP I/O
screen
section. Options of Enabled and Disabled are available for selection. The Enabled option must
be selected to use the functionality provided by the board.
Tap the arrow to the right of the field to display the drop down list of options and select the
option to be used.
■
Units
The metal detector is able to work with imperial or metric units. Tap the arrow to the right of the
field to display the drop down list of unit options and select the option to be used.
■
Band
Frequency bands are used to prevent crosstalk between adjacent metal detectors that are
operating on the same frequency.
Tap the arrow to the right of the field to display the drop down list of options and select the band
to be used.
The options are OFF, or 1 through 10. If OFF is selected then all seventy (70) frequencies, 31
through 882, will be available for use for all products, making frequency selection and
subsequent Learns a manual process.
If a band number is selected then the 7 frequencies available in that band are used by the metal
detector when selecting the optimum inspection frequency for any product.
The available frequencies are banded as listed below, with all values shown in kHz:
O
Band 1:
31, 71, 111, 203, 300, 405 and 576
O
Band 2:
33, 73, 115, 208, 319, 416 and 600
O
Band 3:
35, 75, 121, 211, 326, 428 and 625
O
Band 4:
37, 77, 126, 217, 333, 441 and 652
O
Band 5:
39, 79, 131, 223, 340, 454 and 681
O
Band 6:
41, 81, 136, 231, 348, 468 and 714
O
Band 7:
43, 83, 141, 238, 357, 500 and 750
O
Band 8:
46, 85, 146, 242, 365, 517 and 789
O
Band 9:
48, 87, 151, 250, 375, 535 and 833
O
Band 10:
52, 89, 156, 254, 384, 555 and 882
■
Default frequency
With banding set to OFF the initial operating frequency for all products defaults to the lowest
available of 31KHz. This of course can be changed to whichever frequency it is desired to start
from.
Tap the arrow to the right of the field to display the drop down list of available frequencies and
select the frequency to be used.
When banding is set then it is recommended to set the default frequency as suggested by the
following:
o
Aperture dimension in the range of 75 - 125mm - depending upon the band selected, use
the 405kHz upwards range.
Summary of Contents for IQ3+
Page 2: ......
Page 36: ...Safety First 26 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 43: ...Installation 33 ...
Page 60: ...Installation 50 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 70: ...About the Metal Detector Range 60 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 218: ...Operating Instructions 208 THIS IS PAGE INTENTIONALLY LEFT BLANK ...
Page 244: ...Maintenance 234 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 248: ...Glossary 238 THIS PAGE IS INTENTIONALLY LEFT BLANK ...