Protocols • 171
Gocator 1100 & 1300 Series
Format Value
Explanation
%n
New line
%r
Carriage return
%%
Percentage (%) symbol
Standard Result Format
Measurement results can either be sent in the standard format, or in a custom format. In the standard
format, the users select in the web interface which measurement values and decisions to send. For each
measurement the following message is transmitted:
M
t
n
,
i
n
,
V
v
n
,
D
d
1
CR
Standard Result Format:
Field
Shorthand Length
Description
MeasurementStart
M
1
Start of measurement frame.
Type
t
n
n
Hexadecimal value that identifies the type of measurement. The
measurement type is the same as defined in
Id
i
n
n
Decimal value that represents the unique identifier of the
measurement.
ValueStart
V
1
Start of measurement value. This field and the following Value
field are optional – they will only be present if the measurement
value has been selected for transmission.
Value
v
n
n
Measurement value, in decimal. The unit of the value is
measurement-specific.
DecisionStart
D
1
Start of measurement decision. This field and the following
Decision field are optional – they will only be present if the
measurement decision has been selected for transmission.
Decision
d
1
1
Measurement decision:
0 – Fail
1 – Pass
Custom Result Format
In the custom format, users enter a formatting string with place holders to create a custom message.
The default formatting string is "%time, %value[0], %decision[0]".
Result Placeholders:
Format Value
Explanation
%time
Timestamp
%encoder
Encoder position
%frame
Frame number
%value[Measurement ID]
Measurement value of the specified measurement ID
%decision[Measurement ID]
Measurement decision of the specified measurement ID
Summary of Contents for Gocator 1100 Series
Page 1: ...USER MANUAL Gocator 1100 1300 Series Version 3 6 5 15 Revision C...
Page 187: ...Specifications 187 Gocator 1100 1300 Series Envelope 21 0 40 0 20 0 71 0 2 1 19 3 101 4...
Page 189: ...Specifications 189 Gocator 1100 1300 Series Envelope 0 39 0 87 5 120 7 0 1 2 11 4 40 0 60 0...
Page 191: ...Specifications 191 Gocator 1100 1300 Series Envelope 21 0 182 5 35 0 72 2 102 8 2 8 19 6...
Page 193: ...Specifications 193 Gocator 1100 1300 Series Envelope 0 39 0 88 9 122 2 0 11 8 1 6 182 5 217 5...
Page 196: ...Specifications 196 Gocator 1100 1300 Series Envelope 21 0 200 0 200 0 72 3 103 1 2 8 19 7...
Page 199: ...Specifications 199 Gocator 1100 1300 Series Envelope 0 39 0 88 9 122 6 0 12 0 1 6 200 0 400 0...
Page 202: ...Specifications 202 Gocator 1100 1300 Series Envelope 21 0 237 5 325 0 72 3 103 2 2 8 19 8...
Page 205: ...Specifications 205 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 237 5 562 5...
Page 208: ...Specifications 208 Gocator 1100 1300 Series Envelope 21 0 375 0 562 5 72 6 103 3 3 0 19 9...
Page 211: ...Specifications 211 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 237 5 562 5...
Page 214: ...Specifications 214 Gocator 1100 1300 Series Envelope 400 0 21 0 250 0 72 4 103 3 2 8 19 8...
Page 217: ...Specifications 217 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 250 0 650 0...
Page 220: ...Specifications 220 Gocator 1100 1300 Series Envelope 21 0 500 0 2000 0 200 1 231 4 2 7 19 9...