Protocols • 165
Gocator 1100 & 1300 Series
AssemblyObject(Class0x04)
The Gocator Ethernet/IP object model includes 3 different assembly objects: Command, State and
Sample.
All assembly object instances are static. Data in a data byte array in an assembly object are stored in the
Big Endian format.
c
ommand
o
bject
The command object is used to start, stop, calibrate and switch configuration on the sensor.
Command Assembly
Information
Value
Class
0x4
Instance
0x310
Number of Attributes
3
Length
32 bytes
Supported Service
0x10 (Write Single Attribute)
Attributes 1 and 2 are not implemented. These are not required for static assembly object.
Attribute 3
Attribute Name
Type
Value
Description
Access
3
Command
Byte Array
See Below
Commands parameters
Byte 0 - Command. See table below for
specification of the values.
Byte 1-31 - Used for load configuration
command
Get, Set
Command Definitions
Value
Name
Description
0
Stop running
Stop the sensor. No action if the sensor is already stopped
1
Start Running
Start the sensor. No action if the sensor is already started.
2
Alignment Calibrate Start the calibration process:
Byte 1 of the Sensor State Assembly will be set to 1 (busy) until the calibration process
is complete, then back to zero.
3
Travel Calibrate
Start the travel calibration process:
Byte 1 of the Sensor State Assembly will be set to 1 (busy) until the calibration process
is complete, then back to zero
4
Clear Calibration
Clear the calibration
5
Load Configuration Load a configuration file. Bytes 1 - 31 for the filename: one ASCII character per byte.
File name must be NULL terminated.
If you specify a file ending with the ".cfg" extension, only a configuration will be
loaded, unless you are switching from a configuration whose calibration was
performed with Source set to Current Configuration in the Layout panel (see
"Transformation Sources" on page 78
for more details) to a configuration that uses
global transformations. In the latter case, global transformations will also be loaded.
If you specify a file ending with the ".set" extension, a configuration and the
transformations that were associated with it by performing calibration using Current
Configuration will be loaded.
Summary of Contents for Gocator 1100 Series
Page 1: ...USER MANUAL Gocator 1100 1300 Series Version 3 6 5 15 Revision C...
Page 187: ...Specifications 187 Gocator 1100 1300 Series Envelope 21 0 40 0 20 0 71 0 2 1 19 3 101 4...
Page 189: ...Specifications 189 Gocator 1100 1300 Series Envelope 0 39 0 87 5 120 7 0 1 2 11 4 40 0 60 0...
Page 191: ...Specifications 191 Gocator 1100 1300 Series Envelope 21 0 182 5 35 0 72 2 102 8 2 8 19 6...
Page 193: ...Specifications 193 Gocator 1100 1300 Series Envelope 0 39 0 88 9 122 2 0 11 8 1 6 182 5 217 5...
Page 196: ...Specifications 196 Gocator 1100 1300 Series Envelope 21 0 200 0 200 0 72 3 103 1 2 8 19 7...
Page 199: ...Specifications 199 Gocator 1100 1300 Series Envelope 0 39 0 88 9 122 6 0 12 0 1 6 200 0 400 0...
Page 202: ...Specifications 202 Gocator 1100 1300 Series Envelope 21 0 237 5 325 0 72 3 103 2 2 8 19 8...
Page 205: ...Specifications 205 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 237 5 562 5...
Page 208: ...Specifications 208 Gocator 1100 1300 Series Envelope 21 0 375 0 562 5 72 6 103 3 3 0 19 9...
Page 211: ...Specifications 211 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 237 5 562 5...
Page 214: ...Specifications 214 Gocator 1100 1300 Series Envelope 400 0 21 0 250 0 72 4 103 3 2 8 19 8...
Page 217: ...Specifications 217 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 250 0 650 0...
Page 220: ...Specifications 220 Gocator 1100 1300 Series Envelope 21 0 500 0 2000 0 200 1 231 4 2 7 19 9...