Gocator Device Files • 123
Gocator 1100 & 1300 Series
Output
The Outputs element has the following sub-element types: Ethernet, Serial, Analog, and Digital Output.
Each of these subelements defines the output settings for a different type of Gocator output.
The
Source
identifiers that are used with
Video, range and intensity
outputs are
range source identifiers
.
Refer to the Range Sources (page 132) for more information.
The
Source
identifiers that are used with
Value
and
Decision
outputs correspond to the measurement
identifiers defined in the Measurements element. E.g.
<RangeMeasurement>
...
<Measurements>
<RangePositionZ id=”1000”>
...
<RangeDifference id=”2000”>
...
<Outputs>
<Ethernet>
...
<Decision>1000,2000</Decision>
...
e
theRnet
The Ethernet element defines settings for Ethernet output.
Ethernet Child Elements
Element
Type
Description
Protocol
32s
Setting for selected protocol:
0 – Gocator
1 – Modbus TCP
2 – EtherNet/IP
Video
String
Setting for selected video sources (comma-delimited list).
Range
String
Setting for selected range sources (comma-delimited list).
RangeIntensity
String
Setting for selected range intensity sources (comma-delimited list).
Value
String
Setting for selected value sources (comma-delimited list).
Decision
String
Setting for selected decision sources (comma-delimited list).
AsciiOperation
32s
Setting for the ASCII protocol operation mode:
0 – Asynchronous
1 – Polling
AsciiControlPort
32u
Setting for the ASCII protocol control channel port number.
AsciiHealthPort
32u
Setting for the ASCII protocol health channel port number.
AsciiDataPort
32u
Setting for the ASCII protocol data channel port number.
AsciiDelimiter
String
Setting for the ASCII protocol delimiter character.
AsciiTerminator
String
Setting for the ASCII protocol terminator character.
AsciiInvalidValue
String
Setting for the ASCII protocol invalid value string
AsciiCustomFormatEnabled 32u
Setting for the ASCII custom format
0 – Disable
1 – Enable
AsciiCustomDataFormat
String
Setting for the format of ASCII custom data string.
EIPBufferEnabled
32u
Setting for enable/dissable EIP buffering
0 – Disable
1 – Enable
Summary of Contents for Gocator 1100 Series
Page 1: ...USER MANUAL Gocator 1100 1300 Series Version 3 6 5 15 Revision C...
Page 187: ...Specifications 187 Gocator 1100 1300 Series Envelope 21 0 40 0 20 0 71 0 2 1 19 3 101 4...
Page 189: ...Specifications 189 Gocator 1100 1300 Series Envelope 0 39 0 87 5 120 7 0 1 2 11 4 40 0 60 0...
Page 191: ...Specifications 191 Gocator 1100 1300 Series Envelope 21 0 182 5 35 0 72 2 102 8 2 8 19 6...
Page 193: ...Specifications 193 Gocator 1100 1300 Series Envelope 0 39 0 88 9 122 2 0 11 8 1 6 182 5 217 5...
Page 196: ...Specifications 196 Gocator 1100 1300 Series Envelope 21 0 200 0 200 0 72 3 103 1 2 8 19 7...
Page 199: ...Specifications 199 Gocator 1100 1300 Series Envelope 0 39 0 88 9 122 6 0 12 0 1 6 200 0 400 0...
Page 202: ...Specifications 202 Gocator 1100 1300 Series Envelope 21 0 237 5 325 0 72 3 103 2 2 8 19 8...
Page 205: ...Specifications 205 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 237 5 562 5...
Page 208: ...Specifications 208 Gocator 1100 1300 Series Envelope 21 0 375 0 562 5 72 6 103 3 3 0 19 9...
Page 211: ...Specifications 211 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 237 5 562 5...
Page 214: ...Specifications 214 Gocator 1100 1300 Series Envelope 400 0 21 0 250 0 72 4 103 3 2 8 19 8...
Page 217: ...Specifications 217 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 250 0 650 0...
Page 220: ...Specifications 220 Gocator 1100 1300 Series Envelope 21 0 500 0 2000 0 200 1 231 4 2 7 19 9...