Features: 

1) DXL360S: High accuracy ± (0.08° + 1%), high resolution 0.01° 
    DXL360: ± (0.15° + 1%), resolution 0.02° 
2) Laser Alignment 
3) Dual and Single axis with user friendly LCD display angle 
4) Rechargeable  
5) V Shape metal case for easy to fit at the corner or pipe. 
6) Magnetic base 
7) Audible alarming at settable angle range

 

 

Summary of Contents for DXL360

Page 1: ...cy 0 08 1 high resolution 0 01 DXL360 0 15 1 resolution 0 02 2 Laser Alignment 3 Dual and Single axis with user friendly LCD display angle 4 Rechargeable 5 V Shape metal case for easy to fit at the co...

Page 2: ...rating temperature 0 to 50 C Storage temperature 10 to 60 C User Interface Mono color LCD with backlight Supply Power Rechargeable Li Ion Battery 3 7Volt Charger port 5V 500mA Mini type B USB port Pow...

Page 3: ...d hold for 3 seconds to enable or disable backlight Serves as the upward key for option selection HOLD When pressed the current value will be freezed the unit icon will be flash to indicate the readin...

Page 4: ...to section Angle Alarming ZERO When pressed the current reading is set to zero subsequent measurements are relative to this reading The LCD will show the icon to indicate the device is in zero mode Pr...

Page 5: ...f and full When the In dual axis mode the LCD displays the direction of tilt graphically The unit of scale is displayed below the graph with different scales The scale is adjusted automatically depend...

Page 6: ...rent angle to zero Direction of tilt icons show the tilt angle direction with respect to the unit bottom right hand corner Dual Axis Mode Both the X and Y axis angle will be showed Dual axis mode meas...

Page 7: ...a built in Lithium Ion rechargeable battery A standard charger is supplied that the input voltage is 110V to 240V AC 50 60Hz and the output is 5V DC 500mA The charger operating procedure is list belo...

Page 8: ...to the unit and a computer s USB port This has the same effect when charging the unit with the provided adaptor Note When the unit is turned OFF and plug in the USB charge cable the LCD will no show...

Page 9: ...to cancel the relative zero point and back to absolute measurement mode Hold Function Holding Mode LCD Icon blinking Holding function 1 Press and release the HOLD key to activate holding function dig...

Page 10: ...O key to confirm NEVER or 30MIN 30 minutes sleep Restore Factory Setting When you find that the unit is abnormal you can restore the unit to factory setting All calibration setting will be restored to...

Page 11: ...irm Angle Alarming Alarming Mode LCD Icon Alarming Angle setting 1 Press and hold ZERO key and enter MENU mode 2 Select BUZZER by ON OFF and HOLD key press ZERO key to enter BUZZER setting Press and h...

Page 12: ...al axis mode X axis alarming angle Degree DUAL Y Horizontal Dual axis mode Y axis alarming angle Degree RANGE The range Degree that will trigger the audible alarming For example SINGLE set to 20 00 RA...

Page 13: ...curacy drift on the unit You can verify the accuracy at below step At Step1 you measured X and Y value X1 and Y1 At Step2 you measured X2 and Y2 in theory X1 X2 Y1 Y2 If the error is too large you can...

Page 14: ...e Select Calibration mode press ZERO Place the unit on a flat table no need perfect level table LCD display CALIBRATE DUAL AXIS PRESS SET press set and buzzer will beep wait until the beep sound stop...

Page 15: ...PRESS SET Place the unit horizontal like the picture STEP 3 and then press Set wait until the beep sound stop Step 4 Then rotate the unit 180 degree at the same place Press the ZERO button again and w...

Page 16: ...on a flat wall And then press ZERO Key Wait for the Beep sound stop Step 6 Then rotate the unit 180 degree with the other side against the at the same place of wall LCD in upper side Press the Set bu...

Page 17: ...17 selection menu The calibration is done by selecting Back to go back for normal operation A Step 5 Step 6 Wall Wall A...

Page 18: ...18...