Protocols • 149
Gocator 1100 & 1300 Series
R
eStoRe
F
actoRy
The Restore Factory command restores the connected sensor to factory default settings. This command
has no effect on connected Buddy sensors.
Note that the sensor must be reset or power-cycled before the factory restore operation can be
completed.
Command
Field
Type
Description
length
64s
Command size – in bytes.
id
64s
Command identifier (0x4301).
resetAddress
64s
Specifies whether network address should be restored to default:
0 – Do not reset address
1 – Reset address
Reply
Field
Type
Description
length
64s
Reply size – in bytes.
id
64s
Reply identifier.
status
64s
Reply status.
S
et
c
onnection
t
yPe
The Set Connection Type command save the type of the master to the sensor's non-volatile storage.
Command
Field
Type
Description
length
64s
Command size – in bytes.
id
64s
Command identifier (0x4514).
type
64s
Connection type:
0 – None
1 – Master 100
2 – Master 200
3 – Master 400
4 – Master 800
5 – Master 1200
6 – Master 2400
Reply
Field
Type
Description
length
64s
Reply size – in bytes.
id
64s
Reply identifier.
status
64s
Reply status.
g
et
c
onnection
t
yPe
The Get Connection Type command returns to the set connection type.
Command
Field
Type
Description
length
64s
Command size – in bytes.
id
64s
Command identifier (0x4515).
Summary of Contents for Gocator 1100 Series
Page 1: ...USER MANUAL Gocator 1100 1300 Series Version 3 6 5 15 Revision C...
Page 187: ...Specifications 187 Gocator 1100 1300 Series Envelope 21 0 40 0 20 0 71 0 2 1 19 3 101 4...
Page 189: ...Specifications 189 Gocator 1100 1300 Series Envelope 0 39 0 87 5 120 7 0 1 2 11 4 40 0 60 0...
Page 191: ...Specifications 191 Gocator 1100 1300 Series Envelope 21 0 182 5 35 0 72 2 102 8 2 8 19 6...
Page 193: ...Specifications 193 Gocator 1100 1300 Series Envelope 0 39 0 88 9 122 2 0 11 8 1 6 182 5 217 5...
Page 196: ...Specifications 196 Gocator 1100 1300 Series Envelope 21 0 200 0 200 0 72 3 103 1 2 8 19 7...
Page 199: ...Specifications 199 Gocator 1100 1300 Series Envelope 0 39 0 88 9 122 6 0 12 0 1 6 200 0 400 0...
Page 202: ...Specifications 202 Gocator 1100 1300 Series Envelope 21 0 237 5 325 0 72 3 103 2 2 8 19 8...
Page 205: ...Specifications 205 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 237 5 562 5...
Page 208: ...Specifications 208 Gocator 1100 1300 Series Envelope 21 0 375 0 562 5 72 6 103 3 3 0 19 9...
Page 211: ...Specifications 211 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 237 5 562 5...
Page 214: ...Specifications 214 Gocator 1100 1300 Series Envelope 400 0 21 0 250 0 72 4 103 3 2 8 19 8...
Page 217: ...Specifications 217 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 250 0 650 0...
Page 220: ...Specifications 220 Gocator 1100 1300 Series Envelope 21 0 500 0 2000 0 200 1 231 4 2 7 19 9...