Gocator Web Interface • 108
Gocator 1100 & 1300 Series
If multiple decision sources are selected and assert mode is set to pass, the output is activated when
all selected measurement decisions pass. Conversely, if assert mode is set to false, the output is
activated when any one of the selected measurement decisions is false.
4
Specify a Signal type.
The signal type specifies whether the digital output is a continuous signal or a pulsed signal. If the
signal is continuous its state is maintained until the next transition occurs. If the signal is pulsed, the
user specifies the pulse width and how it is scheduled.
5
Specify a Pulse Width.
The pulse width is the duration of the digital output pulse, in microseconds.
6
Specify whether the output is Immediate or Scheduled.
A pulsed digital output can be immediate or scheduled. Check the Scheduled option if the output
needs to be scheduled.
A scheduled output becomes active after a specified delay from the start of Gocator exposure. A
scheduled output can be used to track the decisions for mutliple objects as these objects travel from
the sensor to the eject gates. The delay specifies the distance from the sensor to the eject gates.
An Immediate output becomes active as soon as measurement results are available. The output
activates after the sensor finishes processing the data. As a result, the time between the start of
sensor exposure and output activates can vary and is dependent on the processing latency. The
latency is reported in the dashboard and in the health messages.
7
Specify a Delay.
The delay specifies the time or spatial location between the start of sensor exposure and when the
output becomes active. The delay should be larger than the time needed to process the data inside the
sensor. It should be set to a value that is larger than the processing latency reported in the dashboard
or in the health messages.
The unit of the delay is configured in the trigger panel. Refer to
Trigger Panel (page 65) for details.
To output a measurement valid signal:
1
Navigate to the Digital Output 0 or Digital 1 panel.
2
Set Event to Measurement.
3
Set Assert On to Always.
4
Select decision sources.
The output activates when the selected decisions produce results. The output activate only once for
each frame even if multiple decision sources are selected.
5
Specify a Pulse Width.
The pulse width determines the duration of the digital output pulse, in microseconds.
Summary of Contents for Gocator 1100 Series
Page 1: ...USER MANUAL Gocator 1100 1300 Series Version 3 6 5 15 Revision C...
Page 187: ...Specifications 187 Gocator 1100 1300 Series Envelope 21 0 40 0 20 0 71 0 2 1 19 3 101 4...
Page 189: ...Specifications 189 Gocator 1100 1300 Series Envelope 0 39 0 87 5 120 7 0 1 2 11 4 40 0 60 0...
Page 191: ...Specifications 191 Gocator 1100 1300 Series Envelope 21 0 182 5 35 0 72 2 102 8 2 8 19 6...
Page 193: ...Specifications 193 Gocator 1100 1300 Series Envelope 0 39 0 88 9 122 2 0 11 8 1 6 182 5 217 5...
Page 196: ...Specifications 196 Gocator 1100 1300 Series Envelope 21 0 200 0 200 0 72 3 103 1 2 8 19 7...
Page 199: ...Specifications 199 Gocator 1100 1300 Series Envelope 0 39 0 88 9 122 6 0 12 0 1 6 200 0 400 0...
Page 202: ...Specifications 202 Gocator 1100 1300 Series Envelope 21 0 237 5 325 0 72 3 103 2 2 8 19 8...
Page 205: ...Specifications 205 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 237 5 562 5...
Page 208: ...Specifications 208 Gocator 1100 1300 Series Envelope 21 0 375 0 562 5 72 6 103 3 3 0 19 9...
Page 211: ...Specifications 211 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 237 5 562 5...
Page 214: ...Specifications 214 Gocator 1100 1300 Series Envelope 400 0 21 0 250 0 72 4 103 3 2 8 19 8...
Page 217: ...Specifications 217 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 250 0 650 0...
Page 220: ...Specifications 220 Gocator 1100 1300 Series Envelope 21 0 500 0 2000 0 200 1 231 4 2 7 19 9...