LTC3882-1
31
Rev A
OPERATION
Factory Default Operation
The LTC3882-1 ships from the factory with a default con-
figuration stored in its non-volatile memory, unless custom
programming has been requested. These command values
are loaded into volatile RAM when the chip is initialized. Prior
to receiving any PMBus commands, a stock LTC3882-1 will
operate in the factory default mode. If a STORE_USER_
ALL command is executed, the contents of the non-volatile
memory are replaced with active command values from
internal RAM, and that will permanently overwrite the factory
defaults. Table 5 summarizes the default factory operation
settings of the LTC3882-1 if all resistor configuration pins
are left open. These defaults allow parameters listed in bold
text in the table to be overridden with configuration resistor
programming. Warning limits are given in Table 5 because
exceeding them will cause the
ALERT
pin to be asserted even
if the PMBus interface is not being utilized.
Table 5. Factory Default Operation Summary
PARAMETER*
DEFAULT SETTING
UNITS
PMBus Address
All writes enabled to Channel 0 at address 0x4F (no PEC).
–
Operation
OPERATION enabled with RUN pin control and soft-off.
–
Input Voltage OFF Threshold
6.0
V
Input Voltage UV Warning Limit
6.3
V
Input Voltage ON Threshold
6.5
V
Input Voltage OV Fault Limit
15.5
V
Input Voltage OV Fault Response
Latch off.
–
Soft-Start Time
8 (with no delay).
ms
Maximum Start-Up Time (TMAX)
10
ms
TMAX Fault Response
Retry every 350ms.
–
Output Voltage UV Fault/Warning Limits
0.900/0.925
V
Output Voltage UV Fault Response
Retry every 350ms.
–
Output Voltage
1.000
V
Active Voltage Positioning
Disabled.
–
Output Voltage OV Warning/Fault Limits
1.075/1.100
V
Output Voltage OV Fault Response
Retry every 350ms.
–
Shut Down
8ms soft-off.
–
Output Current Sense Element
0.63mΩ with 3930ppm/°C TC.
–
Output Current OC Warning/Fault Limits
20/29.75
A
Output Current OC Fault Response
Ignore
–
PWM Switching Mode
Continuous inductor current only.
–
PWM Control Protocol
Three-State PWM.
–
PWM Switching Frequency
500
kHz
Channel 0/1 Phase
0/180
Degrees
Internal Overtemperature Warning/Fault Limits
130/160
°C
Internal Overtemperature Responses
Warning: EEPROM disabled; Fault: PWM disabled.
–
External Undertemperature Fault Limit
–40
°C
External Undertemperature Fault Response
Retry every 350ms.
–
External Overtemperature Warning/Fault Limits
85/100
°C
External Overtemperature Fault Response
Retry every 350ms.
–
FAULT
Asserts low for the following faults: V
OUT
UV or OV, V
IN
OV, external or internal OT,
external UT, TON_MAX, or output short cycle.
–
ALERT
Masking
ALERTs are masked for loss of PLL lock and external
FAULT
inputs.
–
*bold entries can be changed with external configuration resistors