LTC3882-1
103
Rev A
PMBus COMMAND DETAILS
(EEPROM User Access)
MFR_ID
The MFR_ID command returns the manufacturer ID of the LTC3882-1 using 8-bit ASCII characters.
This read-only command is in block format.
MFR_MODEL
The MFR_MODEL command returns the LTC part number using 8-bit ASCII characters.
This read-only command is in block format.
MFR_SERIAL
The MFR_SERIAL command returns the serial number of this specific device using a maximum of fourteen 8-bit ASCII
characters.
This read-only command is in block format.
MFR_SPECIAL_ID
The MFR_SPECIAL_ID command returns a 16-bit word representing the part name. 0x424X denotes the part is a
LTC3882-1. X is adjustable by the manufacturer. This read-only command has 2 data bytes.
UNIT IDENTIFICATION
COMMAND NAME
CMD
CODE DESCRIPTION
TYPE
PAGED
DATA
FORMAT UNITS NVM
DEFAULT
VALUE
MFR_ID
0x99 Manufacturer identification.
R String
N
ASC
LTC
MFR_MODEL
0x9A LTC model number.
R String
N
ASC
LTC3882-1
MFR_SERIAL
0x9E Device serial number.
R Block
N
Reg
MFR_SPECIAL_ID
0xE7 Manufacturer code representing the LTC3882-1
R Word
N
Reg
0x424X
PMBus COMMAND DETAILS
(Unit Identification)
MFR_FAULT_LOG_STORE
The MFR_FAULT_LOG_STORE command forces a data log to be written to internal EEPROM as if a fault event had occurred.
This command will generate a CML fault if the Enable Fault Logging bit is cleared in MFR_CONFIG_ALL_LTC3882-1.
This write-only command has no data bytes.
MFR_EE_xxxx
The MFR_EE_xxxx commands facilitate bulk programming of the LTC3882-1 internal EEPROM. Contact the factory for details.
USER_DATA_0x
The USER_DATA_0x commands provide uncommitted EEPROM locations that may be applied as system scratchpad
space. USER_DATA_00 and USER_DATA_01 should not be modified when using the LTpowerPlay GUI. Some contract
manufacturers also reserve use of USER_DATA_02 for their own inventory control.