Troubleshooting Guide
128
Indoor Unit
Indoor Unit drain
pump error
Error
Code
Error Contents
Meaning
Main Causes
Error display
position
04
In case of the Indoor Unit
drain pump defect the con-
densed water level rises and
float switch (sensor) detects
the error .
Concerned
Remote controller
Panel Display
1. Defective drain pump / float switch
2. Defective drain (hose chocked /
improper inclination )
3. Defective PCB in the Indoor Unit
■
Defect inspection method :
1) Check the proper functioning of the drain pump in case of any drain water? (Functioning sound / check the
water flowing)
2) In case the drain pump is not working properly, then check the 220V power supply at the drain pump terminal
with a tester.
In case the drain pump do not function properly after power supply to the to the PCB, then replace the drain
pump.
3) In case of no power at the PCB terminal, then replace the Indoor Unit PCB.
4) In case the drain pump is OK, then check whether the hose is chocked or the drain pipe is improper and make
sure to correct the drain flow error if any.
5) In case the drain pump is OK and there is no drain water in drain pan and still the error code is displayed?
Then check whether the float sensor is touching the chassis. In case the float switch sensor is not touching the
chassis and still the error code exists, then the float switch has the error. In such a case, the drain pump
assembly must be replaced.
Drain Pump connector
Summary of Contents for ARNU Series
Page 13: ...Service Manual 13 External Appearance 2 2 Outdoor Units ARUN1008F20 10HP ...
Page 16: ...16 ...
Page 17: ...Service Manual 17 Indoor Units ...
Page 18: ...18 Indoor Unit ...
Page 30: ...30 Indoor Unit ...
Page 44: ...44 Indoor Unit ...
Page 79: ...Service Manual 79 Outdoor unit ...
Page 88: ...88 Outdoor Unit 5 Wiring Diagrams Wiring Diagrams ...
Page 112: ...112 Outdoor Unit ...
Page 113: ...Service Manual 113 Trouble shooting guide ...
Page 137: ...Service Manual 137 Troubleshooting Guide Resistance measure between phases of compressor ...
Page 142: ...Troubleshooting Guide 142 Outdoor Unit Connector of reactor Connectors of 3phase diode ...
Page 143: ...Service Manual 143 Troubleshooting Guide Connectors of capacitor Check IPM PCB ...
Page 150: ...Troubleshooting Guide 150 Outdoor Unit Pressure switch CHECK VALVE ...
Page 152: ...Troubleshooting Guide 152 Outdoor Unit Measure power input of outdoor unit ...
Page 153: ...Service Manual 153 Troubleshooting Guide Measure power input of outdoor unit ...
Page 156: ...Troubleshooting Guide 156 Outdoor Unit Liquid injection by pass valve ...
Page 157: ...Service Manual 157 Troubleshooting Guide Measure resistance of LEV coil ...
Page 158: ...Troubleshooting Guide 158 Outdoor Unit Heater ...
Page 168: ...Troubleshooting Guide 168 Outdoor Unit Measure input power of outdoor unit ...
Page 172: ...Troubleshooting Guide 172 Outdoor Unit Check main fuse of out door unit ...
Page 176: ...Troubleshooting Guide 176 Outdoor Unit Fan IPM ...
Page 178: ...Troubleshooting Guide 178 Outdoor Unit Measure input power of fan main PCB ...
Page 183: ...Service Manual 183 Exploded View Replacement Parts List ...