Service Manual
111
Replacement procedure for Compressor
1) Collect the refrigerant by using refrigerant recov-
ery unit
(Since the setting on outdoor unit PCB is required for
refrigerant recovery, refer to the warming plate
"
Precautions in service work
"
attached on the switch
box cover)
2) Remove the sound insulator mat covering the
faulty compressor, and disconnect the power
3) Disconnect the brazing sections of suction pipe
and discharge pipe by using brazing torch after the
refrigerant has been collected completely.
4) Remove equalizing pipe.
5) Remove three bolts at cushion rubber section to
take out the faulty compressor outside the unit.
6) Install the new compressor in the unit.(Be sure to
insert the cushion rubbers before tightening the
fixing bolts of compressor.)
7) Remove the rubber caps put on the suction and
discharge pipe of the new compressor to
release.the sealing nitrogen gas.(Take note that oil
may spout due to the pipe inside pressure if the
plug put on the equalizing seat is removed before
removing of rubber cap.)
8) Braze equalizing pipe with nut.
9) Braze the suction and discharge pipe with brazing
torch to the compressor.
Cut section
10) Conduct air tight test to check the piping system
is free from leakage.
11) Connect power cable to the terminal board of
compressor and cover the compressor with
sound insulator mat.
12) Conduct vacuum drying.(Since the setting on out-
door unit PCB is required for vacuum drying, refer
to the warning plate recautions in service work”
attached on the switch box cover.)
13) Charge refrigerant after the completion of vacuum
drying, and check the function of compressor
with cooling or heating operation.
Replacement procedure for Compressor
Discharge pipe
Suction pipe
Equalizing pipe
Summary of Contents for ARNU Series
Page 13: ...Service Manual 13 External Appearance 2 2 Outdoor Units ARUN1008F20 10HP ...
Page 16: ...16 ...
Page 17: ...Service Manual 17 Indoor Units ...
Page 18: ...18 Indoor Unit ...
Page 30: ...30 Indoor Unit ...
Page 44: ...44 Indoor Unit ...
Page 79: ...Service Manual 79 Outdoor unit ...
Page 88: ...88 Outdoor Unit 5 Wiring Diagrams Wiring Diagrams ...
Page 112: ...112 Outdoor Unit ...
Page 113: ...Service Manual 113 Trouble shooting guide ...
Page 137: ...Service Manual 137 Troubleshooting Guide Resistance measure between phases of compressor ...
Page 142: ...Troubleshooting Guide 142 Outdoor Unit Connector of reactor Connectors of 3phase diode ...
Page 143: ...Service Manual 143 Troubleshooting Guide Connectors of capacitor Check IPM PCB ...
Page 150: ...Troubleshooting Guide 150 Outdoor Unit Pressure switch CHECK VALVE ...
Page 152: ...Troubleshooting Guide 152 Outdoor Unit Measure power input of outdoor unit ...
Page 153: ...Service Manual 153 Troubleshooting Guide Measure power input of outdoor unit ...
Page 156: ...Troubleshooting Guide 156 Outdoor Unit Liquid injection by pass valve ...
Page 157: ...Service Manual 157 Troubleshooting Guide Measure resistance of LEV coil ...
Page 158: ...Troubleshooting Guide 158 Outdoor Unit Heater ...
Page 168: ...Troubleshooting Guide 168 Outdoor Unit Measure input power of outdoor unit ...
Page 172: ...Troubleshooting Guide 172 Outdoor Unit Check main fuse of out door unit ...
Page 176: ...Troubleshooting Guide 176 Outdoor Unit Fan IPM ...
Page 178: ...Troubleshooting Guide 178 Outdoor Unit Measure input power of fan main PCB ...
Page 183: ...Service Manual 183 Exploded View Replacement Parts List ...