![Lenze 931M Series Communications Manual Download Page 87](http://html1.mh-extra.com/html/lenze/931m-series/931m-series_communications-manual_1882301087.webp)
Parameter setting
Digital inputs and outputs
Description of the objects
7
87
KHB 13.0003-EN 2.0
Characteristics
Possible settings
Name
Index
Description
Selection
Lenze
2006
h
0 local_input_
function
0
-128
{1}
127
VAR
INT8
RW
—
Digital input can be
parameterised by the user.
Value
Function
Active
-128 ... -9
Reserved
-8
Start/stop
Low
-7
Reserved
-6
Stopover
Low
-5
Synchronisation
Low
-4
Reserved
-3
Quick stop
Low
-2
Power stage off
Low
-1
Reference
Low
0
No function
1
Reference
High
2
Output stage off
High
3
Quick stop
High
4
Reserved
5
Synchronisation
High
6
Stopover
High
7
Reserved
8
Start/stop
High
9 ... 127
Reserved