CANopen communication
Emergency telegram
Description of the objects
5
51
KHB 13.0003-EN
2.0
5.6.2
Description of the objects
Index
Name
Possible settings
Characteristics
Lenze
Selection
Description
1001
h
0 error_register
VAR
UINT8
RO
MAP
Here, you can read the value
of the error_register
contained in the emergency
telegram.
Bit No.
Meaning
0
generic error
An error has occurred which
is not specified in detail
(flag is set with every error
message).
1
current
2
voltage
3
temperature
4
communication error
Communication error (CAN
overrun).
5
device profile-specific
6
reserved
7
manufacturer-specific
Manufacturer-specific error.
1003
h
Pre_defined_error_
field
0 number_of_errors
00
h
{1
h
}
FF
h
UINT8
RW
—
Reading the number of error
messages saved.
00
h
Deleting the history buffer
by writing the value 00
h
.
After an error, the error
must be acknowledged to
activate the power stage.
1 standard_error_
field_0
—
UINT32 RO
—
Reading the last error
message.
Bit
31 ... 24 23 ... 16 15 ... 8
7 ... 0
00
00
23
00
Motor deenergised due to
overcurrent
00
00
32
10
DC-bus voltage > 400 V
00
00
32
20
DC-bus voltage < 180 V
00
00
33
20
20 V > brake voltage > 28 V
00
00
42
10
Power stage
overtemperature
00
00
43
10
Motor overtemperature
00
00
63
20
Driving program, system
parameters
00
00
71
21
Drive inhibited
00
00
90
00
Quick stop
00
00
FF
00
Homing
...
4 standard_error_
field_3
—
UINT32 RO
—
Reading the error message.