![Lenze 931M Series Communications Manual Download Page 148](http://html1.mh-extra.com/html/lenze/931m-series/931m-series_communications-manual_1882301148.webp)
Appendix
Index table
10
148
KHB 13.0003-EN 2.0
Characteristics
Possible settings
Name
Index
Description
Selection
Lenze
6098
h
0 homing_method
35
1
{1}
35
VAR
INT8
RW
MAP
Value
Direction
Target
Reference point for zero
1
negative Limit
switch
Zero pulse
Selecting the variant for
homing.
Four homing signals are
distinguished:
z
negative and positive
limit switch
z
reference switch
z
(periodic) zero pulse of
the phase-angle
encoder.
Homing to the limit stop is
only possible with the
”fluxx” software.
When defining a homing
method, the following
settings are selected:
z
Reference source
(neg./pos. limit switch,
reference switch, neg. /
pos. limit stop)
z
Direction and sequence
of homing
z
The way, the zero pulse
of the phase-angle
encoder is evaluated.
2
positive
Limit
switch
Zero pulse
4
positive
Referen
ce
switch
Zero pulse
6
negative Referen
ce
switch
Zero pulse
9
positive
Referen
ce
switch
Zero pulse
11
negative Referen
ce
switch
Zero pulse
17
negative Limit
switch
Limit switch
18
positive
Limit
switch
Limit switch
20
negative/
positive
Referen
ce
switch
Reference switch
22
negative Referen
ce
switch
Reference switch
23
positive
Referen
ce
switch
Limit switch
27
negative Referen
ce
switch
Limit switch
32
negative Zero
pulse
Zero pulse
33
positive
Zero
pulse
Zero pulse
35
No run. Current actual
position