![Lenze 931M Series Communications Manual Download Page 58](http://html1.mh-extra.com/html/lenze/931m-series/931m-series_communications-manual_1882301058.webp)
CANopen communication
Node Guarding
Description of the objects
5
58
KHB 13.0003-EN 2.0
5.9.1
Description of the objects
Index
Name
Possible settings
Characteristics
Lenze
Selection
Description
100C
h
0 guard_time
0
0
{1 ms}
65535
VAR
UINT16 RW
—
Setting the cyclic monitoring
time in which the master
queries the status of the
slaves.
0
Function is deactivated.
100D
h
0 life_time_factor
0
0
{1}
255
VAR
UINT8
RW
—
The maximum time between
two queries of the master
results from the product of
guard_time and
life_time_factor.
0
Function is deactivated.
6007
h
0 abort_connection_
option_code
0
0
{1}
3
VAR
INT16
RW
MAP
Determining the event to be
activated when the master
fails.
0
No action
1
Malfunction: Control word = 0
2
Device control command: Disable
voltage
3
Device control command: Quick stop