Commissioning
Position control
Parameterising of the homing run
6
67
KHB 13.0003-EN 2.0
No. Description
Identifier Control
field
Command
code
Index
Subindex Data 1 Data 2 Data 3 Data 4
Data
length
Low
byte
High
byte
1
Status check (reading)
Every status change must be
carried out depending on the
basic status. After a status
change, you have to wait until
the status change is indicated in
the status word.
601
4
40
41
60
00
00
00
00
00
2
Control word: Shut down
With the shut down command,
the status is changed to
Ready_To_Switch_On
.
601
6
2B
40
60
00
06
80
00
00
3
Status check (reading)
(for explanation see 1)
601
4
40
41
60
00
00
00
00
00
4
Control word: Switch on
With the
switch on
command,
the status is changed to
Switched_On
.
601
6
2B
40
60
00
07
80
00
00
5
Status check (reading)
(for explanation see 1)
601
4
40
41
60
00
00
00
00
00
6
Control word: Enable operation
With the
enable operation
command, the status is changed
to
Operation_Enable
.
Now, the motor is energised.
But, homing is not started yet.
601
6
2B
40
60
00
0F
80
00
00
7
Status check (reading)
(for explanation see 1)
601
4
40
41
60
00
00
00
00
00
8
Control word: Enable operation
and homing start
With the
enable operation and
homing start
command, homing
is started.
601
6
2B
40
60
00
1F
80
00
00
9
Status check (reading)
The home position is
approached. Homing is
completed when bit 12 (homing
attained) is set in the status
word.
601
4
40
41
60
00
00
00
00
00
10
Control word: Disable voltage
With this command, the drive is
switched off and set to the
status
Switch_On_Disabled
.
601
6
2B
40
60
00
00
80
00
00
Tab. 7
Execution of homing by means of the status machine