Appendix
Index table
10
137
KHB 13.0003-EN
2.0
Characteristics
Possible settings
Name
Index
Description
Selection
Lenze
2006
h
0 local_input_
function
0
-128
{1}
127
VAR
INT8
RW
—
Digital input can be
parameterised by the user.
Value
Function
Active
-128 ... -9
Reserved
-8
Start/stop
Low
-7
Reserved
-6
Stopover
Low
-5
Synchronisation
Low
-4
Reserved
-3
Quick stop
Low
-2
Power stage off
Low
-1
Reference
Low
0
No function
1
Reference
High
2
Output stage off
High
3
Quick stop
High
4
Reserved
5
Synchronisation
High
6
Stopover
High
7
Reserved
8
Start/stop
High
9 ... 127
Reserved
2007
h
0 absolute_
resolver_position
-1
{1 inc}
VAR
INT16
RW
—
Determining the absolute
resolver position within
one revolution.
2008
h
Maximum_control _
difference
0 number_of_
supported_entries
00
h
{1
h
}
02
h
VAR
UINT8
RO
—
Maximally supported
subindices.
02
h
Three subindices are
supported.
1 maximum_
positive_
control_difference
{1 rpm}
VAR
UINT1
6
RW
—
Set the setting to 0 to start
measurement.
2 maximum_
negative_
control_difference
{1 rpm}
VAR
UINT1
6
RW
—
Set the setting to 0 to start
measurement.