![Lenze 931M Series Communications Manual Download Page 86](http://html1.mh-extra.com/html/lenze/931m-series/931m-series_communications-manual_1882301086.webp)
Parameter setting
Digital inputs and outputs
Description of the objects
7
86
KHB 13.0003-EN 2.0
Characteristics
Possible settings
Name
Index
Description
Selection
Lenze
2005
h
0 local_output_
function
0
-128
{1}
127
VAR
INT8
RW
—
Digital output can be
parameterised by the user.
Value
Function
Active
-128 ... -17
Reserved
-16
Reference set
Low
-15 ... -14
Reserved
-13
Stopover
Low
-12
Motor
deenergised
Low
-11
Controller error
Low
-10
Reserved
-9
Drive in standstill Low
-8
Reserved
-7
Homing active
Low
-6 ... -5
Reserved
-4
Setpoint reached
Low
-3
Traversing request
is being processed Low
-2
Fault
Low
-1
Warning
0
No function
1
Warning
High
2
Fault
High
3
Traversing request
is being processed High
4
Setpoint reached
High
5 ... 6
Reserved
7
Homing active
High
8
Reserved
9
Drive in standstill High
10
Reserved
11
Controller error
High
12
Motor
deenergised
High
13
Stopover
14 ... 15
Reserved
16
Reference set
High
17 ... 127
Reserved