Parameter setting
Digital inputs and outputs
Overview
7
85
KHB 13.0003-EN 2.0
7.7
Digital inputs and outputs
7.7.1
Overview
All digital controller inputs can be read via the CAN bus and the digital outputs can be set
as you choose.
7.7.2
Description of the objects
Index
Name
Possible settings
Characteristics
Lenze
Selection
Description
60FD
h
0 digital_inputs
00000000
h
{1}
FFFFFFFF
h
VAR
UINT32 RO
MAP
Reading the digital inputs.
Bit No.
Digital input
0
Neg. limit switch
High-active
1
Pos. limit switch
High-active
2
Reference switch
3
Interlock (no
controller or
power stage
enable)
High-active
4 ... 15
Reserved
16
Brake_on
17
DOUT0
18 ... 31 Reserved
60FE
h
Digital_outputs
0 number_of_
supported_entries
00
h
{1
h
}
02
h
VAR
UINT8
RO
—
Maximally supported
subindices.
02
h
Three subindices are
supported.
1 digital_outputs_
data
0
00000000
h
{1
h
}
FFFFFFFF
h
VAR
UINT32 RW
MAP
Bit No.
Digital output
Activating or deactivating
special functionalities or
outputs.
With bit 0, you can, for
instance, activate or
deactivate the brake.
0
Brake
1 ... 15
Reserved
16
DOUT0
17
Neg. limit switch
18
Pos. limit switch
19
Reference switch
20
Quick stop
17 ... 31 Reserved
2 digital_outputs_
mask
0
0
{1}
1
VAR
UINT32 RW
MAP
Defining a mask to ensure
that an output is not
activated when this is not
desired.
0
Output is not selected
1