CANopen communication
Process data transfer (PDO transfer)
Objects for PDO parameterisation
5
26
KHB 13.0003-EN 2.0
1. Transmit PDO
Index
Name
Possible settings
Characteristics
Lenze
Selection
Description
1800
h
Transmit PDO1
communication
parameters
0 number_of_entries
00
h
{1
h
}
05
h
REC
UINT8
RO
—
Maximally supported
subindices.
05
h
Six subindices are supported.
1 COB-ID_used_by_
PDO
80000181
h
80000181
h
{1
h
}
800001FF
h
—
UINT32 RW
—
Identifier of transmit PDO1,
(180
h
+ node address).
For processing, bit 31 must
be set (parameterisation of
mapping).
Bit No.
Value
0 - 10
X
11-bit identifier
11 - 28
0
The extended identifier
(bit 29) is not supported.
Every bit in this range must
be set to ”0”.
29
0
30
0
Set to zero.
31
0
PDO active
1
PDO inactive
2 transmission_type FF
h
0
{1}
F0
h
, FE
h
, FF
h
—
UINT8
RW
—
Setting the transmission
mode.
0
Function is deactivated.
n = 1 ... F0
When a value n is entered,
the PDO is accepted every
n-th sync.
n = FE
Cyclic transmission mode.
n = FF
Event-controlled
transmission mode.
3 inhibit_time
0
0
{100
μ
s}
65535
—
UINT16 RW
—
Setting the minimum delay
time between two PDOs. The
time can only be changed
when the PDO is not active
(subindex 1, bit 31 = 1).
4 CMS_priority_
group_tpdo1
0
0
{1}
255
—
UINT8
RW
—
5 event_timer
0
0
{1 ms}
65535
—
UINT16 RW
—
Setting the maximum delay
time between two PDOs.
0
Function is deactivated.