Appendix
Index table
10
139
KHB 13.0003-EN
2.0
Characteristics
Possible settings
Name
Index
Description
Selection
Lenze
200F
h
0 remote_request
0
{1}
1
VAR
UINT8
RW
MAP
Requesting the control
authority.
Cannot be saved (when
the controller is restarted,
the control authority has
to be requested again).
Value
Meaning
1
Requesting the control
authority via the CAN bus
Bit 15 of the control word
need not be set to ”1”.
The control authority can
still only be requested via
bit 15 of the control word.
0
Not requesting the control
authority via the CAN bus
207A
h
Manual_drive_
positions
0 number_of_
supported_entries
00
h
{1
h
}
02
h
VAR
UINT8
RO
—
Maximally supported
subindices.
02
h
Three subindices are
supported.
1 negative_manual_
drive_position
VAR
INT32
RW
MAP
2 positive_manual_
drive_position
VAR
INT32
RW
MAP
2081
h
0 manual_drive_
velocity
{1 rpm}
VAR
INT32
RW
MAP
2083
h
0 manual_drive_
acceleration
{1 rpm/s}
VAR
UINT3
2
RW
MAP
2084
h
0 manual_drive_
deceleration
{1 rpm/s}
VAR
UINT3
2
RW
MAP
2100
h
0 driving_program_
number
0
0
{1}
99
VAR
UINT8
RW
MAP
Selecting the current
driving program.
Driving program
Meaning
0
Depending on the active
control mode, the setpoints
and profile values of the
objects 6071
h
, 607A
h
,
6081
h
, 6083
h
, 6084
h
and
60FF
h
apply.
1 ... 99
Depending on the active
control mode, the setpoints
and profile values of the
objects 2171
h
, 217A
h
,
2183
h
, 2184
h
and 21FF
h
apply.