11. Save the removed dummy storage-drive tray in the event that you later remove the 2.5-inch drive
and need a dummy tray to cover the drive bay.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To configure RAID, go to “Configuring RAID” on page 63.
Replacing the front-panel board
Attention:
Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii and “Guidelines” on page 67.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
Notes:
• Depending on the model, your server might look slightly different from the illustrations in this topic.
• Use any documentation that comes with the new front-panel board and follow those instructions in
addition to the instructions in this topic.
• The front-panel board is sensitive to ESD. Ensure that you read and understand “Handling static-sensitive
devices” on page 68 first and carefully perform the operation.
To replace the front-panel board, do the following:
1. Remove all external media from the drives and turn off all attached devices and the server. Then,
disconnect all power cords from electrical outlets and disconnect all cables that are connected to
the server.
2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,
clean, and static-protective surface. See the
Rack Installation Instructions
that comes with the server.
3. Remove the server cover. See “Removing the server cover” on page 70.
4. Remove the front bezel. See “Removing and reinstalling the front bezel” on page 74.
5. Locate the front panel. See “Front panel” on page 21.
6. Disconnect the front-panel cable from the rear of the front-panel board and from the front panel
connector on the system board. See “System board components” on page 44.
7. If necessary, remove any parts and disconnect any cables that might impede your access to the front
panel cable. Record the cable routing, and then release the front panel cable from any cable clips
or ties in the chassis.
Chapter 6
.
Replacing hardware
151
Summary of Contents for ThinkServer TD350 70DG
Page 14: ...xii ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 66: ...52 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 192: ...178 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 202: ...188 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 217: ...guidelines 69 Copyright Lenovo 2014 2015 203 ...
Page 218: ...204 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 219: ......
Page 220: ......