Creating a Storage Configuration
4-9
2.
Click
Yes
when you are prompted to save the configuration.
3.
Click
Yes
when you are prompted to initialize the new virtual drive(s).
WebBIOS CU begins a background initialization of the virtual drives.
4.4.3
Using Manual Configuration
The following subsections contain the procedures for creating RAID drive
groups for RAID levels 0, 1, 5, 6, 00, 10, 50, and 60:
•
Section 4.4.3.1, “Using Manual Configuration: RAID 0”
•
Section 4.4.3.2, “Using Manual Configuration: RAID 1”
•
Section 4.4.3.3, “Using Manual Configuration: RAID 5”
•
Section 4.4.3.4, “Using Manual Configuration: RAID 6”
•
Section 4.4.3.5, “Using Manual Configuration: RAID 00”
•
Section 4.4.3.6, “Using Manual Configuration: RAID 10”
•
Section 4.4.3.7, “Using Manual Configuration: RAID 50”
•
Section 4.4.3.8, “Using Manual Configuration: RAID 60”
4.4.3.1
Using Manual Configuration: RAID 0
RAID 0 provides drive striping across all drives in the RAID drive group.
RAID 0 does not provide any data redundancy but does offer excellent
performance. RAID 0 is ideal for applications that require high bandwidth
but do not require fault tolerance. RAID 0 also denotes an independent
or single drive.
Note:
RAID level 0 is not fault-tolerant. If a drive in a RAID 0 drive
group fails, the whole virtual drive (all drives associated
with the virtual drive) fails.
When you select
Manual Configuration
and click
Next
, the drive group
Definition screen appears. You use this screen to select drives to create
drive groups.
1.
Hold <Ctrl> while selecting two or more ready drives in the Drives
panel on the left until you have selected all desired drives for the
drive group.
Summary of Contents for ThinkServer RD230
Page 1: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Page 2: ......
Page 3: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Page 16: ...Contents ...
Page 24: ...Contents ...
Page 68: ...2 36 Introduction to RAID ...
Page 252: ...7 10 MegaRAID Storage Manager Window and Menus ...
Page 300: ...8 48 Configuration ...
Page 328: ...9 28 Monitoring System Events and Storage Devices ...
Page 334: ...10 6 Maintaining and Managing Storage Configurations ...
Page 360: ...B 12 Glossary ...
Page 363: ......
Page 364: ......