RAID Levels
2-17
RAID 10, a combination of RAID 0 and RAID 1, consists of striped data
across mirrored spans. A RAID 10 drive group is a spanned drive group
that creates a striped set from a series of mirrored drives. RAID 10
allows a maximum of eight spans. You must use an even number of
drives in each RAID virtual drive in the span. The RAID 1 virtual drives
must have the same stripe size. RAID 10 provides high data throughput
and complete data redundancy but uses a larger number of spans.
RAID 50, a combination of RAID 0 and RAID 5, uses distributed parity
and disk striping. A RAID 50 drive group is a spanned drive group in
which data is striped across multiple RAID 5 drive groups. RAID 50
works best with data that requires high reliability, high request rates, high
data transfers, and medium-to-large capacity.
Note:
Having virtual drives of different RAID levels, such as RAID
0 and RAID 5, in the same drive group is not allowed.
For example, if an existing RAID 5 virtual drive is created
out of partial space in an array, the next virtual drive in the
array has to be R5 only.
RAID 60, a combination of RAID 0 and RAID 6, uses distributed parity,
with two independent parity blocks per stripe in each RAID set, and disk
striping. A RAID 60 virtual drive can survive the loss of two drives in each
of the RAID 6 sets without losing data. It works best with data that
requires high reliability, high request rates, high data transfers, and
medium-to-large capacity.
2.5.2
Selecting a RAID Level
To ensure the best performance, you should select the optimal RAID
level when you create a system drive. The optimal RAID level for your
drive group depends on a number of factors:
•
The number of drives in the drive group
•
The capacity of the drives in the drive group
•
The need for data redundancy
•
The disk performance requirements
Summary of Contents for ThinkServer RD230
Page 1: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Page 2: ......
Page 3: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Page 16: ...Contents ...
Page 24: ...Contents ...
Page 68: ...2 36 Introduction to RAID ...
Page 252: ...7 10 MegaRAID Storage Manager Window and Menus ...
Page 300: ...8 48 Configuration ...
Page 328: ...9 28 Monitoring System Events and Storage Devices ...
Page 334: ...10 6 Maintaining and Managing Storage Configurations ...
Page 360: ...B 12 Glossary ...
Page 363: ......
Page 364: ......