9-24
Monitoring System Events and Storage Devices
•
The current BBU temperature, voltage, current, and remaining
capacity
•
If the battery is charging, the estimated time until it is fully charged
9.8.1
Battery Learn Cycle
Learn Cycle is a battery calibration operation performed by the controller
periodically to determine the condition of the battery. You can start
battery learn cycles manually or automatically. To choose automatic
battery learn cycles, enable automatic learn cycles. To choose manual
battery learn cycles, disable automatic learn cycles.
If you enable automatic learn cyles, you can delay the start of the learn
cycles for up to 168 hours (7 days). If you disable automatic learn cycles,
you can start the learn cycles manually, and you can choose to receive
a reminder to start a manual learn cycle.
9.8.1.1
Setting Learn Cycle Properties
To set the learn cycle properties, perform the following steps:
1.
Click the
Physical
tab to open the physical view.
2.
Select the BBU icon in the left panel.
3.
Click the
Operations
tab.
The BBU operations appear, as shown in
Figure 9.15
.
Summary of Contents for ThinkServer RD230
Page 1: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Page 2: ......
Page 3: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Page 16: ...Contents ...
Page 24: ...Contents ...
Page 68: ...2 36 Introduction to RAID ...
Page 252: ...7 10 MegaRAID Storage Manager Window and Menus ...
Page 300: ...8 48 Configuration ...
Page 328: ...9 28 Monitoring System Events and Storage Devices ...
Page 334: ...10 6 Maintaining and Managing Storage Configurations ...
Page 360: ...B 12 Glossary ...
Page 363: ......
Page 364: ......