RAID Configuration Strategies
2-29
2.6.2
Maximizing Performance
A RAID disk subsystem improves I/O performance. The RAID drive
group appears to the host computer as a single storage unit or as
multiple virtual units. I/O is faster because drives can be accessed
simultaneously.
Table 2.14
describes the performance for each RAID
level.
6
Combines distributed parity with disk striping. RAID 6 can sustain two drive failures and
still maintain data integrity. Parity provides redundancy for two drive failures without
duplicating the contents of entire drives. If a drive fails, the RAID controller uses the
parity data to reconstruct all missing information. In RAID 6, this method is applied to
entire drives or stripes across all of the drives in a drive group. Using distributed partiy,
RAID 6 offers fault tolerance with limited overhead.
00
Does not provide fault tolerance. All data in a virtual drive is lost if any drive in that
virtual drive fails. Disk striping writes data across multiple drives instead of just one
drive. It involves partitioning each drive storage space into stripes that can vary in size.
RAID 00 is ideal for applications that require high bandwidth but do not require fault
tolerance.
10
Provides complete data redundancy using striping across spanned RAID 1 drive
groups. RAID 10 works well for any environment that requires the 100 percent
redundancy offered by mirrored drive groups. RAID 10 can sustain a drive failure in
each mirrored drive group and maintain drive integrity.
50
Provides data redundancy using distributed parity across spanned RAID 5 drive groups.
RAID 50 includes both parity and disk striping across multiple drives. If a drive fails, the
RAID controller uses the parity data to recreate all missing information. RAID 50 can
sustain one drive failure per RAID 5 drive group and still maintain data integrity.
60
Provides data redundancy using distributed parity across spanned RAID 6 drive groups.
RAID 60 can sustain two drive failures per RAID 6 drive group and still maintain data
integrity. It provides the highest level of protection against drive failures of all of the
RAID levels. RAID 60 includes both parity and disk striping across multiple drives. If a
drive fails, the RAID controller uses the parity data to recreate all missing information.
RAID
Level
Fault Tolerance
Summary of Contents for ThinkServer RD230
Page 1: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Page 2: ......
Page 3: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Page 16: ...Contents ...
Page 24: ...Contents ...
Page 68: ...2 36 Introduction to RAID ...
Page 252: ...7 10 MegaRAID Storage Manager Window and Menus ...
Page 300: ...8 48 Configuration ...
Page 328: ...9 28 Monitoring System Events and Storage Devices ...
Page 334: ...10 6 Maintaining and Managing Storage Configurations ...
Page 360: ...B 12 Glossary ...
Page 363: ......