5-8
MegaRAID Command Tool
5.4.5
Set Controller Properties
This command sets the properties on the selected controller(s).
For example, for
{RebuildRate -val}
, you can enter a percentage
between 0 percent and 100 percent as the value for the rebuild rate.
(The rebuild rate is the percentage of the compute cycles dedicated to
rebuilding failed drives.) At 0 percent, the rebuild is done only if the
system is not doing anything else. At 100 percent, the rebuild has a
higher priority than any other system activity.
Note:
Lenovo recommends the default rebuild rate of 30 percent, and
the default patrol read rate of 30 percent.
Use the command in
Table 5.7
to display the list of properties you can
set for the controller(s).
Description
Flushes the controller cache on the selected controller(s).
Table 5.6
Cache Flush on Selected Controller (Cont.)
Table 5.7
Set Controller Properties
Convention
MegaCli –AdpSetProp {CacheFlushInterval –val}|{RebuildRate -val}|
{PatrolReadRate –val}|{BgiRate –val}|{CCRate –val}| {ReconRate –val}|
{SpinupDriveCount –val}|{SpinupDelay –val}|{CoercionMode –val} |
{ClusterEnable –val}|{PredFailPollInterval –val}| {BatWarnDsbl –val}|
{EccBucketSize –val}|{EccBucketLeakRate –val}|{AbortCCOnError
–val}|AlarmEnbl | AlarmDsbl | AlarmSilence |{SMARTCpyBkEnbl –val} |
-AutoDetectBackPlaneDsbl | -CopyBackDsbl | -LoadBalanceMode
| NCQEnbl | NCQDsbl | {SSDSMARTCpyBkEnbl -val} |
{MaintainPdFailHistoryEnbl -val} | {EnblSpinDownUnConfigDrvs -val} |
{EnblSSDPatrolRead -val} | AutoEnhancedImportEnbl |
AutoEnhancedImportDsbl | {-UseFDEOnlyEncrypt -val} | {-
PrCorrectUncfgdAreas -val} | -aN| -a0,1,2|-aALL
Summary of Contents for ThinkServer RD230
Page 1: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Page 2: ......
Page 3: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Page 16: ...Contents ...
Page 24: ...Contents ...
Page 68: ...2 36 Introduction to RAID ...
Page 252: ...7 10 MegaRAID Storage Manager Window and Menus ...
Page 300: ...8 48 Configuration ...
Page 328: ...9 28 Monitoring System Events and Storage Devices ...
Page 334: ...10 6 Maintaining and Managing Storage Configurations ...
Page 360: ...B 12 Glossary ...
Page 363: ......
Page 364: ......