Creating a Storage Configuration
4-49
◊
Read Only
:
Allow read-only access. This is the default.
◊
Blocked
:
Do not allow access.
•
Read Policy:
Specify the read policy for this virtual drive:
◊
Normal
:
This disables the read ahead capability. This is the
default.
◊
Ahead
:
This enables read ahead capability, which allows the
controller to read sequentially ahead of requested data and
to store the additional data in cache memory, anticipating
that the data will be needed soon. This speeds up reads for
sequential data, but there is little improvement when
accessing random data.
◊
Adaptive
:
When Adaptive read ahead is selected, the
controller begins using read ahead if the two most recent
drive accesses occurred in sequential sectors. If the read
requests are random, the controller reverts to
Normal
(no
read ahead).
•
Write Policy:
Specify the write policy for this virtual drive:
◊
WBack
:
In Writeback mode the controller sends a data
transfer completion signal to the host when the controller
cache has received all of the data in a transaction.
This setting is recommended in Standard mode.
◊
WThru
:
In Writethrough mode the controller sends a data
transfer completion signal to the host when the drive
subsystem has received all of the data in a transaction.
This is the default.
◊
Bad BBU
: Select this mode if you want the controller to use
Writeback mode but the controller has no BBU or the BBU
is bad. If you do not choose this option, the controller
firmware automatically switches to Writethrough mode if it
detects a bad or missing BBU.
Caution:
Lenovo allows Writeback mode to be used with or without a
battery. It is recommended that you use
either
a battery to
protect the controller cache, or an uninterruptible power
supply (UPS) to protect the entire system. If you do not use
a battery or a UPS, and there is a power failure, you risk
losing the data in the controller cache.
Summary of Contents for ThinkServer RD230
Page 1: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Page 2: ......
Page 3: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Page 16: ...Contents ...
Page 24: ...Contents ...
Page 68: ...2 36 Introduction to RAID ...
Page 252: ...7 10 MegaRAID Storage Manager Window and Menus ...
Page 300: ...8 48 Configuration ...
Page 328: ...9 28 Monitoring System Events and Storage Devices ...
Page 334: ...10 6 Maintaining and Managing Storage Configurations ...
Page 360: ...B 12 Glossary ...
Page 363: ......
Page 364: ......