Remove a hot-swap drive
Use this information to remove a hot-swap drive.
About this task
Attention:
• Read the following section(s) to ensure that you work safely.
–
–
“Installation Guidelines” on page 51
• To avoid damage to the drive connectors, make sure that the server top cover is in place and fully closed
whenever you install or remove a simple-swap drive.
• For proper system cooling, do not operate the server for more than 2 minutes without either a drive or a
filler panel installed in each bay.
• Before you remove or make changes to drives, drive controllers (including controllers that are integrated
on the system board), drive backplanes or drive cables, back up all important data that is stored on drives.
• Before you remove any component of a RAID array, back up all RAID configuration information.
Note:
Make sure you have the drive bay fillers available if some drive bays will be left empty after the
removal.
Watch the procedure
A video of this procedure is available at YouTube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
Procedure
Step 1. Remove the hot-swap drive.
Note:
Install a drive bay filler or replacement drive as soon as possible. See
.
Figure 59. 2.5-inch hot-swap drive removal
72
ThinkSystem SR250 V2 Maintenance Manual
Summary of Contents for 7D7Q
Page 1: ...ThinkSystem SR250 V2 Maintenance Manual Machine Types 7D7Q and 7D7R ...
Page 8: ...vi ThinkSystem SR250 V2 Maintenance Manual ...
Page 20: ...12 ThinkSystem SR250 V2 Maintenance Manual ...
Page 42: ...34 ThinkSystem SR250 V2 Maintenance Manual ...
Page 176: ...168 ThinkSystem SR250 V2 Maintenance Manual ...
Page 180: ...172 ThinkSystem SR250 V2 Maintenance Manual ...
Page 183: ......
Page 184: ......